USE AND MAINTENANCE MANUAL
4.1 PRESSURE DISCHARGE PROCEDURES
When stopping the system to carry out operations on the unit, or when stopping it at the end
of the working day, the high pressure inside the unit must be completely discharged. When
the main air inlet is shut off, the air is automatically discharged from the pump motor.
WARNING
The product in the flexible tube is still under pressure.
PROCEED AS FOLLOWS:
1
Lock spray gun lever with the safety trigger lock (4) (see pag. 7).
2
Shut off the air supply to the equipment.
3
Unlock the lever safety bolt.
4
Take a metal bucket, make sure it is firmly fixed on the ground and keep the spray gun
pressed tightly against the walls of the bucket. Pull lever to discharge the product.
4.2 ROUTINE MAINTENANCE
The routine maintenance of the K1 3A MIX gun is simple and does not require special
operations because its components do not need to be lubricated. Clean the gun daily or at
the end of each working session so that product residues will not dry out on its walls, thus
guaranteeing long term efficiency.
CLEANING:
Unscrew the cap clamping ring, remove the self-cleaner and dismantle the nozzle. Place
everything in the thinner. Carefully clean the nozzle, dip it in thinner to dissolve residues inside
of it. Blow commpressed air throught it from the front to eliminate all traces of material. The
nozzle must be daily mounted back on with its gasket. Clean the head of the gun and the tip of
the nozzle with the provided brush; at least once a week dismantle and clean the product
needle too. Reassemble the gun, lubricate the threads with a thin layer of oil, and close tightly.
DO NOT USE POINTED METAL OBJECTS TO CLEAN CLOGGED PASSAGE HOLES.
THESE OPERATIONS WOULD DAMAGE THEM, REDUCING THE SPRAYING
QUALITY.
Clean the body of the pump with a cloth soaked in thinner. In case industrial washers are used
to clean the gun, close the fan adjustment and the needle adjustment tightly by turning them
clockwise in order to avoid thinner infiltrations which in the long run may damage gaskets.
Once in a while, lubricate the threaded parts such as the cap clamping ring, the needle adjustment
and the air valve cap (including the dip rod) with a thin layer of synthetic oil, in order to avoid
seizing up caused by the effect of thinners on the gun components.
THE LUBRICANTS USED MUST NOT CONTAIN SILICONE.
WARNING
IF THE NEED ARISES CALL THE ASTURO ORIGINALI MAVES Spa CUSTOMER CARE
SERVICE.
®
Page 12 of 14