Austa AU-1P20002G-208-US Manual de instalação e operação - Página 7

Procurar online ou descarregar pdf Manual de instalação e operação para Inversor Austa AU-1P20002G-208-US. Austa AU-1P20002G-208-US 13 páginas.

Step 4 – Ground the system
Each AU-1P20002G has an integrated ground protection circuit.The grounding
wire is through the trunk cable, and should be securely connected to the
groundconnector in the junction box.
Step 5 – Ground the system through racking (option)
AU-1P20002G may also be grounded through the racking as shown below.
08
Step 6 – Complete the connection map and connect the PV Modules
AU-1P20002G connection Map is a diagrammatic representation of the physical
location of each AU-1P20002G in your PV installation. The virtual array in Austa
micro inverter gateway AUG-256 is created from the map you create.
Complete the connection map
Each AU-1P20002G has a removable serial number label located on the mounting
plate. Enter this serial number into the AUG-256, and correspond it to a number in
the connection map.

Connect the PV Modules

Completely install all AU-1P20002G and all system inter-wiring connections prior to
installing the PV modules.
1. Mount the PV modules above their corresponding AU-1P20002G. Each
AU-1P20002G comes with two oppositely sexed DC connectors.
2. First connect the positive DC wire from the PV module to the negatively marked
DC connector (male pin) of the AU-1P20002G. Then connect the negative DC wire
from the PV module to the positively marked DC connector (female socket) of the
AU-1P20002G. Repeat for all remaining PV modules using one AU-1P20002G for
each module.
09