Gage Bilt GB808HVB Manual de instruções - Página 8

Procurar online ou descarregar pdf Manual de instruções para Gerador portátil Gage Bilt GB808HVB. Gage Bilt GB808HVB 20 páginas.

WARNING:
Only qualified and trained operators shall install, adjust or use the assembly power tool for non-threaded
mechanical fasteners.
WARNING:
Operator
WARNING:
It is required that eye protection, hearing protection and foot protection be worn during operation.
WARNING:
The users or the user's employer must assess specific risks that could be present as a result after each use
based on their application.
● Ensure there is adequate clearance for tool and operator's hands before proceeding. Keep fingers clear of any
moving parts. Keep fingers clear from fasteners and installed materials. Severe personal injury may result.
● Verify that hydraulic hose fittings and couplings, air and electrical connections are secure.
● Verify
Ensure that there are no electrical cables, gas pipes, etc., which can cause a hazard if damaged by the tool.
Ensure Do not use as a hammer to force fasteners into holes or otherwise abuse tool.
WARNING:
Do not actuate fastener in the air. Personal injury from fastener ejecting may occur.
WARNING:
Do not use in explosive atmosphere.
WARNING:
Ensure air hose is securely connected to avoid possible hose whipping.
WARNING:
Always disconnect air supply when tool is not in use to prevent accidental start-up.
CAUTION:
Do not use beyond the design intent.
The powerunit is shipped with a red plastic plug in the air inlet connector. The connector has a 1/4 - 18 NPT female pipe thread to
accept end-user air hose fitting. The powerunit comes with oil and is ready to use.
1. See installation tool manual for complete set up installation instructions.
Connect pintail evacuation
tube to tool
Air flows from tool and into
four-way valve when actuator
depressed. When actuator is
released, four-way valve
spring returns
Connect air line to tool
Air flows from regulator and
into tool
Connect hydraulic line to tool
Hydraulic oil flows from booster
assembly thru hydraulic line into
tool
When actuator in tool is released,
return pressure begins air flow from
four-way valve thru valve on front of
powerunit and into vacuum regulator
Tool rests on hook when not in use,
shutting off air flow to vacuum
GB808HVB INSTALLATION TOOL

HOW TO SET-UP THE GB808 SERIES POWER UNIT

MUST
read and understand all warnings and cautions.
the air lines and/or hydraulic hoses are not a trip hazard.
Pintails extracted from tool and
col-
lected in collection bottle
oil reservoir
Air flow pushes booster assembly
piston back to RETURN position
Images may not reflect actual tool
Open oil reservoir cap &
fill reservoir
Four-Way Valve
hydraulic
direction of RETURN
pressurization
direction of
PULL
pressurization
PULL/RETURN
Booster Assembly
8
Pintail Collection bottle
Air Filter/Regulator
Incoming Plant Air
90 PSI (6.2 bar) Min.
Air flow pushes booster assembly
piston forward to PULL position
2/18 REV 2/23