MISCELLANEOUS SYSTEM FIELDS (*174-*181)
✱ 174 CLEAN ME REPORTING OPTIONS
(for ESL smoke detectors)
✱ 177 DEVICE DURATION 1, 2
(used in *80 Menu mode-Device Actions 5/6)
✱ 181 50/60 HERTZ AC OPERATION
CONFIGURABLE ZONE TYPE OPTIONS (*182-*185)
✱ 182 CONFIGURABLE ZONE TYPE 90
✱ 183 ZONE TYPE 90 REPORT CODES
IMPORTANT: Use existing Contact ID®
codes, if appropriate, or define unique codes
in CID code range 750-789. See important
note in installation instructions.
✱ 184 CONFIGURABLE ZONE TYPE 91
✱ 185 ZONE TYPE 91 REPORT CODES
IMPORTANT: Use existing Contact ID®
codes, if appropriate, or define unique codes
in CID code range 750-789. See important
note in installation instructions.
SYMPHONY (AUI) ENABLE
✱ 189 Symphony (AUI) ENABLE
(VISTA-20PS Only)
KEYPAD OPTIONS *190-*196 (NOTE: Options for keypad address 16 are set by the factory and cannot be changed.)
NOTE: Each keypad must be assigned a unique address. Keypads programmed with the same address will give
unpredictable results.
✱ 190 KEYPAD 2 DEVICE ADDRESS 17
✱ 191 KEYPAD 3 DEVICE ADDRESS 18
✱ 192 KEYPAD 4 DEVICE ADDRESS 19
✱ 193 KEYPAD 5 DEVICE ADDRESS 20
✱ 194 KEYPAD 6 DEVICE ADDRESS 21
✱ 195 KEYPAD 7 DEVICE ADDRESS 22
✱ 196 KEYPAD 8 DEVICE ADDRESS 23
✱ 197 EXIT TIME DISPLAY INTERVAL
✱ 198 DISPLAY PARTITION NUMBER
(for Alpha Display Keypads)
✱ 199 ECP FAIL DISPLAY
www.PDF-Zoo.com
0 = disable; 1 = Clean Me signal reports;
[0]
Note: If Clean Me is enabled, you must enter "3" in
field ✱56 programming for zone 1 response time.
0 = 15 seconds
[0] [0]
1 = 30 seconds
1
2
2 = 45 seconds
3 = 60 seconds
4 = 90 seconds
5 = 2 minutes
0 = 60 Hz; 1 = 50 Hz
[0]
1
2
3
4
Enter the appropriate value for each entry, 1-10, based on the charts provided on the
next page. Each entry is the sum of the values of its selected options
(0-9, #+10=10, #+11=11, #+12=12, #+13=13, #+14=14, #+15=15).
UL: Do not configure zones as a fire alarm or UL burglar alarm zone.
Enter the desired 3-digit Contact ID® report codes for
90 ALARM ID: XXX
alarms and troubles occurring on zones assigned to
TROUBLE ID: XXX
this zone type. Enter the codes sequentially (all 6
digits). When entering digits, [#] moves cursor back, [∗]
moves forward. Press [∗] when done to continue.
1
2
3
4
Enter the appropriate value for each entry, 1-10, based on the charts provided on the
next page. Each entry is the sum of the values of its selected options
(0-9, #+10=10, #+11=11, #+12=12, #+13=13, #+14=14, #+15=15).
UL: Do not configure zones as a fire alarm or UL burglar alarm zone.
Enter the desired 3-digit Contact ID® report codes for
91 ALARM ID: XXX
alarms and troubles occurring on zones assigned to
TROUBLE ID: XXX
this zone type. Enter the codes sequentially (all 6
digits). When entering digits, [#] moves cursor back, [∗]
moves forward. Press [∗] when done to continue.
Enter each AUI's home partition.
[0] [0]
0 = disabled
AUI 1
AUI 2
1 = partition 1; 2 = partition 2; 3 = partition 3 (common)
NOTE: A minimum of one standard keypad must also be
installed when AUI is used.
[0] [0]
Partition/
Sound
†
Enable
†VISTA-20P: enter partition
VISTA-15P: 1 = enable
0 = disable
†
Part./Enable
Sound
[0] [0]
[0] [0]
[0] [0]
[0] [0]
[0] [0]
[0] [0]
[0]
[0]
[0]
– 7 –
6 = 2-1/2 min
7 = 3 min
8 = 4 min
9 = 5 min
#+10 = 6 min
5
6
7
8
9
5
6
7
8
9
Partition: 0 = keypad disabled; 1-3 = part. no. (3 = com)
Sound:
0 = no suppression
1 = suppress arm/disarm and E/E beeps
2 = Suppress chime beeps only
3 = suppress arm/disarm, E/E, and chime
beeps
See field ∗190 for entries.
See field ∗190 for entries.
See field ∗190 for entries.
See field ∗190 for entries.
See field ∗190 for entries.
See field ∗190 for entries.
0 = no display; 1-5 = seconds between display refresh
0 = no; 1 = yes (partition no. appears on Alpha Display)
0 = 3-digit display ("1" + device address)
1 = 2-digit fixed-display as "91"
#+11 = 7 min
#+12 = 8 min
#+13 = 10 min
#+14 = 12 min
#+15 = 15 min
10