MAINTAINING PROPER OPERATION
To maintain the 5852 sensor in proper working condition, it is
important to observe the following:
1.
Replace the battery when the system indicates that the 5852
has reported a low battery condition.
2.
Units should never be relocated without the advice or
assistance of the alarm service company.
3.
Fans, air conditioners, blowers, loudspeakers, or other
sources of vibration and sound should not be introduced
into the protected area after installation of sensors. If this
is unavoidable, the alarm service company should be
notified and the system should be readjusted/re-tested.
SPECIFICATIONS
Types of Glass:
Ordinary Plate, Tempered, Wired Plate, and
Laminated
NOTE: The 5852 is NOT recommended
for protection of glass areas less than
10-7/8 inches by 10-7/8 inches.
Power:
Single 9V Lithium Battery:
UltraLife U9VL-J.
WARNING: Risk of fire, explosion, and
burns.
incinerate, or heat above 212° F (100° C).
Dispose of used batteries promptly. Keep
away from children.
Range:
Within 25 feet (7.6 m) of farthest protected
glass
Operating Temp: 32° to 120° F
Dimensions:
4.75" L x 4.13" W x 1.25" D (70mm x
125mm x 27mm)
Accessories:
Ademco GBS7 or Intellisense FG-701
(not supplied) Glassbreak Simulator
¬.99l
K3284V1 11/00
www.PDF-Zoo.com
5852-004-V0
Use only
Do not recharge, disassemble,
firealarmresources.com
*
Glass Type
Minimum
Plate
2.4 mm (3/32 in.)
Tempered
3 mm (1/8 in.)
1
3 mm (1/8 in.)
Laminated
Wired
6 mm (1/4 in.)
2
3 mm (1/8 in.)
Coated
Sealed
1
Insulating
3 mm (1/8 in.)
(Maximum overall 7/16 in.)
*
Minimum size for all types is 28 cm (11 in.) square; glass
must be framed in the wall or mounted in a barrier at least
0.9 m (36 in.) wide.
1
Protected only if both plates of the unit are broken.
2
Coated glass with security films, including films for solar
protection, up to 12 mil. thick may be used. The Glass-Gard
GGLL 1200 has been evaluated with this product by
Underwriters Laboratory, Inc.
FCC NOTICE
FCC ID: CFS8DL5850
This device complies with Part 15 of FCC rules. Operation is
subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
TO THE INSTALLER
Regular maintenance and inspection (at least annually) by the
installer and frequent testing by the user are vital to continuous
satisfactory operation of any alarm system.
The installer should assume the responsibility of developing
and offering a regular maintenance program to the user as well
as acquainting the user with the proper operation and limitations
of the alarm system and its component parts. Recommendations
must be included for a specific program of frequent testing (at
least weekly) to ensure the system's proper operation at all
times.
REFER TO THE INSTALLATION INSTRUCTIONS FOR
THE RECEIVER/CONTROL WITH WHICH THIS DEVICE
IS USED FOR DETAILS REGARDING WARRANTY
INFORMATION AND LIMITATIONS OF THE ENTIRE
ALARM SYSTEM.
165 Eileen Way, Syosset, New York 11791
Copyright © 2000 PITTWAY CORPORATION
Nominal Thickness
Maximum
10 mm (3/8 in.)
10 mm (3/8 in.)
14 mm (3/8 in.)
6 mm (1/4 in.)
6.4 mm (1/4 in.)
6 mm (1/4 in.)