Dynapac CA 250D Manual de oficina - Página 9

Procurar online ou descarregar pdf Manual de oficina para Equipamento de construção Dynapac CA 250D. Dynapac CA 250D 11 páginas. Converting drum std/d to p/pd

Dynapac CA 250D Manual de oficina
FITTING
2
Fig. 12 Scrapers
1. Scraper blade
2. Screws
Fig. 13 Modifying CA 250 to PD

DISMANTLING

Fig. 14 Marking the pad halves
1
16. The pad shell is now fitted and the roller is ready for
Before dismantling the pad shell, mark the halves in
some permanent way to show how they are positioned
in relation to each other.
The hole pattern and any wear to the shell necessitate
refitting the shell to its initial position.
CA 250/252/262 W1065EN2
Adjust the scraper between scraper tooth and drum
shell to a distance of about 20–25 mm (3/4"–1").
It is important to remember that the drum tends
to move as the machine turns. Consequently,
if adjustments are made closer than the values
specified above, the scrapers might be dam-
aged or drum wear may increase.
Torque-tighten the four bolts according to drawing
38 22 20.
operation.
After a short test-run of about 1–1/2 hour,
retighten all of the bolts that have been fitted,
and again after another 4 hours of operation.
This is necessary to compensate certain
settling of the drum shell. If retightening is
neglected, the shell may rotate on the drum
and result in serious damage to the pad shell.
7