Agrowtek SXC Manual de instalação - Página 4
Procurar online ou descarregar pdf Manual de instalação para Registadores de dados Agrowtek SXC. Agrowtek SXC 10 páginas. Climate sensor & data logger
Também para Agrowtek SXC: Manual de instruções (10 páginas)
Connection to USB AgrowLINK
24Vdc 0.5A
Power Supply
LX1 USB AgrowLINK connects Agrowtek's devices to a computer's USB port for:
•
Firmware Updates
•
Calibration
•
Con guration
•
Data Logging Download
•
More
Visit www.agrowtek.com for free software applications.
Standard FTDI drivers automatically install in Windows. GrowNET protocol available for custom software ap-
plications; sample C# code available. See software manual for more information.
Connection to 4-20mA Outputs
Option 1: Use the LX3 Analog Bridge with Mini-Din 6 analog sensor port connection and removable terminal
block for wire connections. Terminal block includes 24V power terminals and four terminals for the analog
channels. 4-20mA linear outputs correspond to the ranges in the speci cations table.
24VDC
4-20mA PLC
ANALOG INPUTS
4
G row N ET™
RJ45
© Agrowtek Inc. | www.agrowtek.com | Technology to Help You Grow™
LX1
U S B
MINI-DIN 6