Airflow 7108A Instruções de instalação - Página 3
Procurar online ou descarregar pdf Instruções de instalação para Ventilador Airflow 7108A. Airflow 7108A 4 páginas. Maxair wall exhaust fan
Também para Airflow 7108A: Garantia e instruções de instalação (4 páginas)
7106A and 7108A
5. Coil the cut PVC sheet around
the wall grille outlet spigot and
slide into retaining clips.
Sticky
Tape
(optional)
6. Screw wall grille outlet to
external wall (appropriate
fasteners to be used for each
installation not provided).
Internal
Sheet to
be approx.
20mm
overlapping
duct
Fan
Assembly
© Clipsal Australia Pty Ltd
MaxAir Wall Exhaust Fan Installation Instructions /Warranty Card
7. Place cover assembly, as shown, over fan
Wall Grille
Outlet
Cover
Assembly
WARNING:
The appliance is not intended for use by
young children or infi rm persons unless
they have been adequately supervised by a
responsible person to ensure that they can
use the appliance safely.
Young children should be supervised to
ensure they do not play with the appliance.
Appliance intended to be mounted on
external wall only.
Ensure the fan is switched OFF from the
supply mains before removing the guard.
NOTE: SHUTTER OPERATION
Do not turn auto switched models on
External
without the front cover fi tted. Auto
switched fans are fi tted with a thermal
actuator, thus requiring approximately
three minutes to fully open and
Wall
approximately sixty seconds to close
Grille
shutters. Pull cord models are operated
Outlet
either by the built in pull cord and/or
separate switch (thermal actuator). If it
is decided to use and operate fan via a
separate switch, the delay on opening and
closing of shutters must also be noted.
assembly and tighten retaining screw.
Test. Ready to go.
Retaining
Screw
Fan
Assembly
3 of 4