IKEA IH8362SS0 Instruções de instalação e manual de utilização e cuidados - Página 7

Procurar online ou descarregar pdf Instruções de instalação e manual de utilização e cuidados para Campânula de ventilação IKEA IH8362SS0. IKEA IH8362SS0 28 páginas. 36" (91.4 cm) wall-mount canopy range hood

7,
Tape template in place, aligning the template centerline and
bottom of template with hood bottom line and with the
centerline marked on the wall.
¸%%¸¸¸
i/iF
C
D
A. Centerline
B. Lower support bracket
C. 5 x 35 mm screws
D. Mounting height reference
E. Fastener locations
F Wall
8=
Place the lower support bracket on the template aligning it
with the traced rectangle. Mark centers of 3 fastener
locations through the template to the wall.
IMPORTANT: All screws must be installed into wood.
Remove the template.
9. Drill %4" (2.75 mm) pilot holes at 2 upper locations where
screws are being installed into wood.
10. Determine and make all necessary cuts in the wall for the vent
system. Install the vent system before installing the hood. See
"Venting Requirements" section.
11. Determine the required height for the 1/2"conduit and drill a
11¼"(3.2 cm) hole at this location.
12. Run the 1/2"conduit through the hole. Run wire through the
1/2"conduit according to the National Electrical Code or CSA
Standards and local codes and ordinances. There must be
enough 1/2"conduit and wires from the fused disconnect
(or
circuit breaker) box to make the connection in the hood's
electrical terminal box.
13. Use caulk to seal all openings.
NOTE: Do not reconnect power until installation is complete.
14. Attach the lower support bracket to the wall using
2 - 5 x 35 mm screws at location marked on the template.
A. Lower support bracket
B. Mounting hooks
C. Adjust side to side.
A. Lower support bracket
B. Centerline on wall
C. 5 x 35 mm screws
Vent Cover Bracket Assembly and Installation
1. Assemble the 3 pieces of the vent cover bracket using 4 -
4 x 8 mm screws provided. The assembled bracket should be
sized to fit inside the upper vent cover.
I
J
2=
A. Vent cover bracket assembly
B. Upper vent cover
C. 4 x 8 mm screws
D. Adjustable width
Install vent cover bracket to wall about 1/8"(3 mm) away from
the ceiling with 2 - 6 x 70 mm screws and 2 - 10 x 70 drywall
anchors supplied.
i
i ...............................
g
I
A. Vent cover bracket
B. Centerline on wall
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
1,
Using 2 or more people, hang blower housing on the lower
support bracket using the 2 mounting hooks on the rear of
the blower housing.
A. Lower support bracket
B. Mounting holes
C. Adjust side to side
D. Adjust up and down
E. Blower housing