draining process, remove
the dipstick (Fig. 8, item 4).
After the oil has been
drained, remove oil resi-
dues from the housing.
Fig. 8
3
8 mm
In case of storage or longer system downtime, the
tank must always be filled sufficiently (dipstick
check – oil level between max and min).
Used hydraulic oil and oil deposits must be properly
disposed of. Hydraulic oil may not enter the ground
or be poured into drains. Hydraulic fluid spills must
be wiped up by suitable material immediately.
6.4
Filling oil
Carefully place the Hydraulic Power Unit in an upright position
(1), so that the vent is at the bottom and the unit flange on
the top. During fill-up, the air must be able to escape from the
tank through the oil drain plug (2). Remove dipstick (Fig. 9).
1
Place a funnel (1) in the oil filler spout (2) and add 3.9 liters
(238 in
) of hydraulic oil „HLP 46" with a measuring jug. Pour
3
in the oil slowly to avoid bottle-neck in the funnel. Since the
funnel cannot be sealed in the opening, oil leakage might
occur. After the filling process, remove the funnel and close
the oil drain plug (3) by turning it clockwise with an 8 mm
NOVA
electrical hydraulic pump
1
5 cm
2
Fig. 8
4
2
Fig. 9
hex head wrench. Recommended torque: 35 Nm (25.8 ft.lbs).
Return the Hydraulic Power Unit carefully to the horizontal
position and install dipstick (4) in clockwise direction (Fig. 10).
3
Finally, check the oil level with the dipstick once
more and add oil if necessary (refer to steps 6.1
and 6.2).
After the oil has been filled, remove oil residue from
the housing.
9
Hydraulic Oil HLP 46
3,9 l
1
2
4
Fig. 10