XIV
iRMC S3, Graphics
Section
Graphic Controller is part of the onboard Management Controller iRMC S3.
Other graphics are not possible.
The iRMC S3 advanced pack is included in the system delivery.
A corresponding license order is not necessary.
XV
Mezzanine cards for Dual Socket Server Blade
Section
The Dual Server Blade supports the following optional mezzanine cards.
A Fibre Channel Switch / Pass-Thru blade, an Ethernet LAN Switch / Pass-Thru blade,
respectively an InfiniBand switch is required in the system unit for this functionality.
SAS Mezz Cards require an SAS switch for each SAS link
SAS Mezz Cards have to be installed in Mezz Card slot 2 on Server Blade
S26361-F4480-E1
PY SAS HBA Mezz Card 6Gb
HBA
SAS 2.0
PCIe Gen2 interface
1x
4x SAS links to midplane
max. 1x per Server Blade
Requires an Ethernet LAN
Switch, IBP or Pass-Thru
Blade for each channel.
S26361-F3331-E1
PY Eth Mezz Card 1Gb 4 Port
2x Intel Zoar controller
4x 10/100/1000 Mbit/s.
pluggable on the main board,
four channel 1Gbit/s
PCIe x4 Interface
max. 2x per Server Blade
S26361-F3997-E1
PY Eth Mezz Card 10Gb 2 Port
Intel 82599EB LAN Controller
2x 10Gbit/s.
pluggable on the main board,
0 - 2x
Dual channel 10Gbit/s
PCIe x8 Interface
max. 2x per Server Blade
S26361-F3592-E532
PY CNA Mezz Card 10Gb 2 Port
Emulex OCe11102 compatible
pluggable on the main board
MC-CNA112E
Dual channel 10Gbit/s
PCIe x8 Interface
max. 2x per Server Blade
R
R: see separate BX900 System Unit configurator, sheet "1 GB Ethernet"
S: see separate BX900 System Unit configurator, sheet "10 GB Ethernet"
T: see separate BX900 System Unit configurator, sheet "Fibre Channel"
U: see separate BX900 System Unit configurator, sheet "InfiniBand"
V: see separate BX900 System Unit configurator, sheet "CB SAS"
https://partners.ts.fujitsu.com/com/order-supply/configurators/primergy_config/current/Pages/default.aspx
S26361-F4531-E30
PY SAS Expander Mezz. Card
for connectivity between
SAS RAID HDD Module and
SAS Connection Blade
4x SAS links to midplane
max. 1x per Server Blade
S26361-F4531-E60
PY Enhanced Mezz Bracket/Riser
max. 1x per Server Blade
Requires a Fibre Channel
Switch for each channel.
S26361-F3874-E1
S26361-F3992-E2
PY FC Mezz Card 8Gb 2 Port
PY IB CX2 Mezz Card 40Gb 2 Port
Emulex LPe12002 compatible
Interface to midplane:
pluggable on the main board,
2x 10Gb/s(SDR), 2x 20Gb/s(DDR)
MC-FC82E
2x 40Gb/s(QDR)
Dual channel 8Gbit/s
Dual channel 40Gbit/s each
PCIe x8 interface
PCIe x8 interface
max. 2x per Server Blade
max. 2x per Server Blade
S
T
Fujitsu PRIMERGY Server
System configurator and order-information guide
PRIMERGY BX920 S3
Status: 2013-12-30
SAS Expander Mezz Card
can only be used with
PY SAS RAID HDD Module
S26361-F4531-E513
Requires an InfiniBand
Switch for each Mezz Card.
S26361-F4534-E1
PY IB CX3 Mezz Card 56Gb 2 Port
Interface to midplane:
2x 10Gb/s(SDR), 2x 20Gb/s(DDR)
2x 40Gb/s(QDR) 2x 56Gb/s(FDR)
Dual channel 56Gbit/s each
PCIe x8 interface
max. 2x per Server Blade
U
V