Deye SUN-5K-SG03LP1-EU Manual do utilizador - Página 19
Procurar online ou descarregar pdf Manual do utilizador para Inversor Deye SUN-5K-SG03LP1-EU. Deye SUN-5K-SG03LP1-EU 19 páginas. Hybrid inverter
Power Factor
Output Frequency and Voltage
Grid type
Current harmonic distortion
Max. Efficiency
Euro Efficiency
MPPT Efficiency
PV Input Lightning Protection
Anti-islanding Protection
PV String Input Reverse Polarity Protection
Insulation Resistor Detection
Residual Current Monitoring Unit
Output Over Current Protection
Output Shorted Protection
Output Over Voltage Protection
Grid Regulation
Safety Regulation
EMC
℃
Operating Temperature Range (
)
Cooling
Noise (dB)
Communication with BMS
Weight (kg)
Size (Width*Height*Depth mm)
Protection Degree
Installation Style
Warranty
0.8 leading to 0.8 lagging
50/60Hz; 220/230/240Vac(single phase)
Single Phase
THD<3%(Linear load) <1.5%
97.60%
96.50%
99.90%
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
VDE 0126,AS4777,NRS2017,G98,G99,
IEC61683, IEC 62116, IEC 61727
IEC62109-1, IEC62109-2
EN61000-6-1, EN61000-6-3
-25~60℃, >45℃ Derating
Fan
<30
RS485; CAN
20.5
580×330×208
IP65
Wall-mounted
5 years
- 33 -