Aqua Logic DSHP Series Manual de instruções de instalação e funcionamento - Página 9
Procurar online ou descarregar pdf Manual de instruções de instalação e funcionamento para Bomba de calor Aqua Logic DSHP Series. Aqua Logic DSHP Series 11 páginas.
Heat pump Trouble Shooting Chart
Symptoms
Heat pump not
functioning
Heat pump running
but has low cooling
Fuses or circuit breaker
Temperature Control
Flow Switch
Pressure Cutout Switch
Compressor
Copyright© 2016 Aqua Logic, Inc. Effective date of 1/2016
Check / Solution
1. OK > Temperature Control.
2. No power > Replace fuses
1. OK > Pressure cutout switch
2. No display > Replace control
3. Check settings.
4. Error code > (see page 6)
1. Pool water flow.
2. Water flow OK > Wiring > Replace flow switch.
1. Check condenser entering water flow and water
temperature.
2. Check for low refrigerant pressure > Check Refrigerant
level.
3. Liquid gauge high pressure > Check water to condenser.
4. No water through condenser> Check water regulating
valve.
5. Reset pressure switch.
*Not running > Check start components > Replace compressor.
1. Clean heat exchanger and or condenser.
2. * Check compressor.
3. * Check refrigerate running pressure levels.
4. Check tank system requirements. Call Aqua Logic for
help.