This section discusses the configuration management commands, which allow you to
configure the zones.
*
The following example shows the cfgSave command, which writes a copy of the
defined configuration and the name of the effective configuration to flash memory in
all fabric switches:
The saved configuration is automatically reloaded by the switch at system start-up. If
a configuration was in effect when it was saved, the same configuration is reinstated
with an automatic cfgEnable command.
NOTE: Dell recommends saving after you enable and test a configuration. Any
unsaved configuration will be lost if the system fails.
-'
The following example shows the cfgEnable command, which enables a specified
configuration:
+ '
The following example shows the cfgDisable command, which disables the current
zone configuration:
The fabric returns to a non-zoned mode, in which all devices see each other.
4-8