Dell PowerEdge M915 Manual de iniciação - Página 9

Procurar online ou descarregar pdf Manual de iniciação para Interruptor Dell PowerEdge M915. Dell PowerEdge M915 12 páginas. Dell poweredge blade servers getting started guide
Também para Dell PowerEdge M915: Notas de lançamento (27 páginas), Manual (25 páginas), Manual do utilizador (23 páginas), Manual de informações importantes (35 páginas), Manual de iniciação (12 páginas), Manual de iniciação (12 páginas), Manual do Proprietário (3 páginas), Manual da carteira (27 páginas), Manual de iniciação (14 páginas)

Dell PowerEdge M915 Manual de iniciação
Power — Blades
Coin-cell battery
Power — Enclosure
AC/DC power supply (per power supply module)
Wattage
Connector
Heat dissipation
Maximum inrush current
System Voltage Requirements
NOTE: This system is also designed to be connected to
IT power systems with a phase to phase voltage not
exceeding 230 V.
DC/DC power supply (per power supply module)
Wattage
Connector
Heat dissipation
Maximum inrush current
System Voltage Requirements
NOTE: Heat dissipation is calculated using the power
supply wattage rating.
Physical — Blades
PowerEdge M915
Height
Width
Depth
Weight (maximum)
PowerEdge M910
Height
Width
Depth
Weight (maximum)
3 V CR2032 Lithium coin cell
2360 W and 2700 W
IEC C20
1205 BTU/hr (maximum)
Under typical line conditions and over the entire system
ambient operating range, the inrush current may reach
55 A per power supply for 10 ms or less.
43 A, 200 V AC to 240 V AC, 50 Hz/60 Hz (2360 W power
supply)
16 A, 100 V AC to 240 V AC, 50 Hz/60 Hz (2700 W power
supply)
2700 W
Molex # 394260002 at PSU end,
mating connector Molex # 39422-0012
1205 BTU/hr (maximum)
Under typical input voltage conditions and over the
entire system ambient operating range, the inrush
current may reach 120 A per power supply for 10 ms or
less.
75 A, 48 V DC to 60 V DC
38.5 cm (15.2 inch)
5 cm (2 inch)
48.6 cm (19.2 inch)
12.7 kg (28 lb)
38.5 cm (15.2 inch)
5 cm (2 inch)
48.6 cm (19.2 inch)
13.1 kg (29 lb)
9