Configure Data Center Bridging (DCB) (optional)
3
Configure Data Center Bridging (DCB) (optional)
To enable DCB mode on the switch, use the commands in this section.
Note: Complete the switch configuration steps in section 2 before configuring the switch for DCB mode.
Note: DCB switch configuration is applicable only for environments with DCB-capable SC Series arrays.
3.1
Disable iSCSI
OS10# configure terminal
OS10(config)# no iscsi enable
OS10(config)# no iscsi session-monitoring enable
3.2
Disable 802.3x flowcontrol on all ports
OS10# configure terminal
OS10(config)# interface range ethernet 1/1/1–1/1/54
OS10(conf-range-eth1/1/1-1/1/54)# no flowcontrol receive
OS10(conf-range-eth1/1/1-1/1/54)# no flowcontrol transmit
OS10(conf-range-eth1/1/1-1/1/54)# exit
OS10(config)#
3.3
Enable DCB
OS10(config)# dcbx enable
3.4
Create tagged VLAN for all ports and port-channels
Note: You must supply a VLAN ID. The valid range is 2-4093.
The following commands configure a single VLAN ID. If desired, multiple VLAN IDs can be created on the
switch and assigned to ports.
OS10(config)# interface vlan <vlan-id>
OS10(conf-if-vl-<vlan-id>)# mtu 9216
OS10(conf-if-vl-<vlan-id>)# no shutdown
OS10(conf-if-vl-<vlan-id>)# exit