Fitting the front facia panel /
lightshield
Screw the hinges (2) supplied to the
left and right hand sides of the front
facia panel / lightshield (1).
With the Miele aluminium lightshield
the screws are supplied.
For lightshields with a Miele kitchen
furniture programme use
3.5 x 16 mm ( 5/8 " ) screws supplied.
Push the Allen screws from the ac-
cessory kit onto the cover caps until
the screw heads lie directly under
the holes in the cover caps.
Hold the front facia panel / light-
shield against the deflector plate:
the holes in the hinges must lie over
the holes visible in the deflector
plate (3).
Secure the cover caps an fascia
panel / lightshield on both sides of
the deflector plate using the Allen
screws.

Dismantling

Disconnect the appliance from the
electricity supply by unplugging at
the socket, or removing the mains
fuse.
Take the dividing wall out of the wall
unit.
Release the hose clip from the ex-
haust connection and push the hose
upwards.
Loosen the securing screws used to
screw the cooker hood to the side
walls.
Pull the deflector plate out to its limit
and remove the grease filters.
Remove the screws now visible
(DA 262 i / DA 272 i = 4;
DA 292 i = 6) using a Philips screw-
driver.
Raise the cooker hood and then
lower it to remove.
Installation