After cleaning
After cleaning, leave the filters on an
absorbent surface to dry.
When removing the filters for
cleaning, also clean off any
accessible oil or fat buildup from the
housing. Doing so will prevent a fire
hazard.
Reinstall the grease filters. When
inserting the filters, make sure that
the locking clip is facing down.
If the filters have been installed
incorrectly, you can insert a small
screwdriver into the slit to disengage
the locking clip.
Resetting the filter saturation
indicator for the grease filters
Once cleaning is complete, the filter
saturation indicator must be reset.
While the blower is turned on, press
the filter saturation indicator for
approx. 3 seconds until 1 is the only
indicator flashing.
The grease filter symbol goes out.
When cleaning the grease filters before
the full operating time has elapsed:
Press the filter saturation
indicator for approx. 6 seconds
until 1 is the only indicator flashing.
Cleaning and care
OdorFree Charcoal Filter
With recirculation mode, a charcoal
filter must be fitted in addition to the
grease filters. The charcoal filter is
designed to absorb cooking odors.
The charcoal filter is fitted in the canopy
above the grease filters.
How to install/replace a charcoal
filter
Remove the grease filters before
fitting or replacing a charcoal filter.
Take the charcoal filter out of its
packaging.
Slide the filter into the back of the
intake frame, then push the front of
the filter up into the frame.
Reinsert the grease filters.