When using the cooker hood at the
same time as another heating ap-
pliance which depends on the air in the
room (eg gas, oil or coal fired heaters,
continuous flow or other water heaters,
gas cooker, gas hob or gas oven), spe-
cial care must be taken as the action of
the cooker hood extracts air from the
room, which these type of heaters need
for combustion.
In order to ensure safe operation, and to
prevent gases given off by the heating
appliances from being drawn back into
the room when the extractor and the
heater are in operation simultaneously,
an underpressure in the room of 0.04
mbar (4pa) is the maximum permissible.
Ventilation can be maintained by air in-
lets which cannot be blocked, in win-
dows, doors and outside wall vents, or
by other technical measures, such as en-
suring that the extractor can only be
switched on when the heating appliance
is switched off or vice-versa.
NB: The overall ventilation condition of
the dwelling must be taken into ac-
count. If in any doubt, the advice of a
competent builder or, for gas, a "Corgi"
installer must be sought.
If the cooker hood is operated in recir-
culation mode only, with active char-
coal filters, these restrictions do not
apply.
Warning and safety instructions
Disposal of your old appliance
Ensure that disconnection from the
mains supply is carried out by a
competent person. Render any plug
useless. Cut off the cable directly be-
hind the appliance to prevent misuse.
The manufacturer cannot be held re-
sponsible for damage caused by
non-observance of these instruct-
ions.
7