Electrical connection

The cooktop is supplied with a mains
connection cable with moulded plug
ready for connection to a suitable
earthed socket.
The socket should be easily accessible
after the cooktop has been installed. If
the socket is not easily accessible,
ensure that a suitable means of
disconnection is provided on the
installation side for each pole.
Risk of fire from overheating.
Connecting the cooktop to multi-
socket adapters or extension cables
can overload the cables.
For safety reasons, do not use an
extension cable or multi-socket
adapter.
Risk of damage from incorrect
connection. Incorrect installation,
maintenance and repairs can be
dangerous to users. Miele cannot be
held liable for damage or injury (e.g.
electric shock) caused by unauthorised
installation, maintenance or repair work,
or by an inadequate or faulty on-site
earthing system.
All electrical work must be carried out
by a suitably qualified and competent
person in strict accordance with
national and local safety regulations.
For safety reasons, we recommend
using a suitable residual current device
(RCD) in the relevant electrical
installation for connecting the cooktop.
20
If the mains connection cable is
damaged, it must only be replaced with
a specific mains connection cable of
the same type (available from Miele).
For safety reasons, such replacement
may only be carried out by a suitably
qualified and competent electrician or a
Miele authorised service technician, in
order to avoid a hazard.
The data plate indicates the nominal
power consumption and the connection
data. Compare this information with the
data of the on-site electrical
connection. If in any doubt, consult a
qualified electrician.
Temporary or permanent operation with
a self-sufficient or non-mains
synchronous energy supply system
(e.g. isolated networks, back-up
systems) is possible. A requirement for
the operation is that the energy supply
system complies with all current local
and national requirements that apply to
stand-alone, solar and/or battery
systems.
The protective measures provided in
the domestic installation and in this
Miele product must also be assured in
their function and operation in isolated
operation or in non-mains synchronous
operation, or replaced with equivalent
measures in the installation.