Miele KM 370 G Manual de instruções de instalação - Página 18
Procurar online ou descarregar pdf Manual de instruções de instalação para Placa de fogão Miele KM 370 G. Miele KM 370 G 32 páginas. Gas
Também para Miele KM 370 G: Manual de Instruções (32 páginas), Manual de Instruções (28 páginas), Manual de Instruções (28 páginas), Manual de Instruções (40 páginas)
Gas Connection
Connection with test point
specifically for GB
Connection with test point
specifically for GB and 90° angle
18
Natural gas / liquid gas
^ The appliance is supplied with an
R 1/2" - ISO 7-1 (DIN 2999) gas
connection point.
^ An appropriate rigid connection and
isolating valve must be installed for
final connection.
^ The gas connection must be so sited
that it is not adversely heated when
the appliance is in operation.
After installing the appliance the gas
burners have to be set for local
conditions.
When the gas hob has been
installed it is essential to check that
neither the gas pipe nor the
electricity cable is in contact with hot
parts of the appliance or hot gas
exhaust, otherwise heat damage to
the pipe and cable could occur.