Overview
®
The new Chroma-Q
Inspire™ Terminal Strip LED house light features a single light engine with 36 high powered LEDs
(RGBW), a fully homogenized optic and controlled via the Inspire™ External Control Box. Through the Inspire External
Control Box, the fixture can be controlled remotely through the ANSI E1.11 USITT DMX 512-A protocol.
2.
Safety
1. This product is for professional use only. It is NOT intended for domestic or outdoor use.
2. The bright flash of light during power-up & continuous strobe may cause epileptic seizure.
Caution
Caution
Caution
Caution
3. This product must be used with a safety cable.
3.
Cabling
System Diagram: (Figure 1)
Power & Data Connections: (Figure 2)
Inspire Terminal Strip Quick Start Guide V1.01
Power Input: (Figure 3)
To connect the wiring for power and control data:
Remove the cover plate for power input.
Maximum DMX cable
•
length from Data Out
Insert the AC power cable with strain relief through the cover plate and connect to the Terminal Block Plug and
•
1/2/3 to the 1st fixture
into the Terminal Block header in the fixture. (Figure 2 & 3)
must not exceed
500'/152m.
Put back and fasten the cover plate
•
Connect the DMX control data cables from the Inspire External Control Box to the Terminal Block Plug and plug
•
into the Terminal Block headers at the rear of the fixture (Figure 2 & 4)
4.
Mounting
A mounting bracket is built into the enclosure for overhead applications. Secure the fixture with a safety bond. A fixing
hold is built into the enclosure.
5.
Optics
The Inspire can be built with either Narrow, Medium or Wide lens. The beam angles are:
Narrow: ~32°; Medium: ~42°; Wide: ~65°
6.
Control
The control functions are accessed through the Touch Screen display at the front panel of the Inspire External Control
Box. The features of the Touch Screen Display are:
Note: The DMX cable
connected to the first Terminal
Strip fixture from each Data
Output of the External Control
Box must be terminated with a
120 ohm resistor. See Inspire
Terminal Strip User Manual
for details.
Control Menu
Main Menu
Address
Inspire Terminal Strip Quick Start Guide V1.01
Control Data: (Figure 4)
Displays the model name, DMX information, AC and Emergency power input and Command buttons
Sets the DMX start address for each output: Output 1, Output 2, Output 3