1.
Overview
®
The new Chroma-Q
Inspire™ Terminal Strip LED house light features a single light engine with 36 high powered LEDs
(RGBW), a fully homogenized optic and controlled via the Inspire™ External Control Box. Through the Inspire External
Control Box, the fixture can be controlled remotely through the ANSI E1.11 USITT DMX 512-A protocol.
2.
Safety
1. This product is for professional use only. It is NOT intended for domestic or outdoor use.
2. The bright flash of light during power-up & continuous strobe may cause epileptic seizure.
Caution
Caution
Caution
Caution
3. This product must be used with a safety cable.
3.
Cabling
System Diagram: (Figure 1)
Power & Data Connections: (Figure 2)
Inspire Terminal Strip Quick Start Guide V1.01
Power Input: (Figure 3)
To connect the wiring for power and control data:
Remove the cover plate for power input.
Maximum DMX cable
length from Data Out
Insert the AC power cable with strain relief through the cover plate and connect to the Terminal Block Plug and
1/2/3 to the 1st fixture
into the Terminal Block header in the fixture. (Figure 2 & 3)
must not exceed
500'/152m.
Put back and fasten the cover plate
Connect the DMX control data cables from the Inspire External Control Box to the Terminal Block Plug and plug
into the Terminal Block headers at the rear of the fixture (Figure 2 & 4)
4.
Mounting
A mounting bracket is built into the enclosure for overhead applications. Secure the fixture with a safety bond. A fixing
hold is built into the enclosure.
5.
Optics
The Inspire can be built with either Narrow, Medium or Wide lens. The beam angles are:
Narrow: ~32°; Medium: ~42°; Wide: ~65°
6.
Control
The control functions are accessed through the Touch Screen display at the front panel of the Inspire External Control
Box. The features of the Touch Screen Display are:
Note: The DMX cable
connected to the first Terminal
Strip fixture from each Data
Output of the External Control
Box must be terminated with a
120 ohm resistor. See Inspire
Terminal Strip User Manual
for details.
Control Menu
Main Menu
Address
Inspire Terminal Strip Quick Start Guide V1.01
Control Data: (Figure 4)
Displays the model name, DMX information, AC and Emergency power input and Command buttons
Sets the DMX start address for each output: Output 1, Output 2, Output 3