AQUATECH ECO 14000 Instruções para o utilizador - Página 4

Procurar online ou descarregar pdf Instruções para o utilizador para Bomba de água AQUATECH ECO 14000. AQUATECH ECO 14000 12 páginas. Eco pond series

The impeller:
Not only to avoid interruptions, but also to ensure a large water capacity, it is important
to clean the impeller regularly. Proceed as follows (see Illustration A):
Switch off the power supply and remove the pump from the pond.
Remove the pump from the housing (pre-filter house) (see illustration B).
Loosen the 4 screws (6).
Remove the impeller housing (9) from the motor housing (1).
Remove the impeller (7) carefully from the motor housing (9).
Clean the impeller under running water with a soft brush.
Clean the impeller housing under running water with a soft brush.
Clean the pump housing carefully under running water with a soft brush.
Assemble all parts in reverse order. Ensure that the impeller is running smoothly in
the motor housing and that the gasket is mounted correctly before you fasten the 4
screws again.
Put the pump back to the pump housing and ensure that all parts and the power
cable are mounted correct. Now the 5 clips can be closed easily.
Spare parts and accessories
No Description
1
Electromotor & housing
2
Nuts 4 pcs
3
Ceramic bearing
4
Gasket
5
Motor support
6
Bolts / screws 4 pcs
7
Impeller ECO 3600
7
Impeller ECO 4800
7
Impeller ECO 7200
1
1
2
2
Illustration A
Illustration A
Article No
AT001280
AT001282
AT001284
AT001286
AT001288
AT001290
AT001261
AT001263
AT001265
3
3
4
4
5
5
No Description
7
Impeller ECO 11000
7
Impeller ECO 14000
7
Impeller ECO 18000
7
Impeller ECO 22000
7
Impeller ECO 25000
8
Gasket
Impeller housing 3600-11000
9
9
Impeller housing 14000-25000
6
6
7
7
Modeltype
on the pump
housing
Article No
AT001267
AT001269
AT001271
AT001273
AT001275
AT001292
AT001294
AT001296
8
8
9
9