The socket is located in the seat box and is attached under the seat.
A 5" carbide core drill makes an excellent clean hole in solid concrete. The centerline of the
socket hole should be _____" from the pool wall or ______" from the edge of the deck. Drill
the hole at least 12"deep. Some customers have found it useful to insert a piece of pipe that is at
least 24" long full depth into the socket. Tape the top end of the socket to the pipe to prevent any
liquid cement from entering the top of the socket. This assures a clean socket interior when the
pipe is removed after the cement is hard. Pour a small amount of anchor cement into the bottom
of the hole. After placing the socket into the hole so that its top edge is flush with the surface of
the deck and the notch in the top of the socket is facing the pool, pour the anchor cement around
the socket. A spirit level should be held along the extension pipe to assure that the socket is
vertically plumb while the cement sets (about 15 minutes). Allow the cement to cure overnight
before proceeding.

LIFT ASSEMBLY

1. Insert lift into socket.
2. Attach seat assembly to cylinder assembly with the bolt provided. Adjust seat height by
choice of hole on piston rod frame. Tighten lock nut securely, making sure bolt has penetrated
nylon insert of lock nut. Two bolt threads should be visible past the nylon insert.
3. On the IGAT-180AD, which normally includes a footrest, first unscrew the T-bolt under the
side of the seat, and then insert the top of the footrest tube into the holder. Slide in to desired
length and turn T-bolt handle clockwise to tighten.
4. If the optional headrest has been ordered, follow the same procedure as footrest to install the
headrest in the headrest bracket on the seat back.
5. Seat belts are installed by sliding the belts through the upper and/or lower slots cut into the
side edges of the seat.

WATER CONNECTIONS

The pool lift is operated by city/household water pressure, with no electricity needed. Our
system is designed for most efficient operation at 60-PSI static pressure or 55 PSI operating
(open flow) pressure to lift 350 lbs. Note that the pressure requirement for a faucet or hose
connection is approximately 10% higher to achieve the rated load.
If your static water pressure measurement is greater than 70 PSI, a reducer must be used between
the water sources and the lift or damage to the lift may result. Purchase a reducer at your local
plumbing supply store. Aquatic Access Inc. is not liable or responsible for damage caused by
excessive water pressure.