Aquatic Access Model IGAT-180
The customer and installer are responsible for assuring the strength of the mounting for the pool
lift and for determining if grounding the unit is necessary. These installation instruction must be
followed to meet advertised lifting capacities.

SOCKET PLACEMENT

The customer or installer and Aquatic
Access mutually agree upon the socket
location. Usually, the customer provides
Aquatic Access with a drawing showing the
measurements and configuration of the deck,
coping, gutter, and pool wall. This allows
our engineers to determine the best location
for the socket. The pool lift should normally
be located where there is at least 36" of
straight vertical pool wall. The depth would
need to be greater if there is a curve instead
of a right angle at the pool bottom. The depth range of 42"– 48" (deck to pool floor) is ideal.
(IN-GROUND AUTOMATIC-TURN OF 180°)

INSTALLATION

It is recommended that the lift be installed 48"
(minimum 36") from inside pool corners and ladders
that could interfere with the turn of the seat. The
socket should not be placed directly on an expansion
joint, but at least 4" away from it. If unsure about the
measurements, configurations or structural integrity,
have a local contractor verify them.
If you have received the socket in advance of the lift
without instructions as to how far away from the pool
edge to install the socket, or if any questions remain,
consult with the engineers at Aquatic Access before
installing the socket.