Cisco UCS B200 M3 Nota de instalação e manutenção - Página 11
Procurar online ou descarregar pdf Nota de instalação e manutenção para Hardware de rede Cisco UCS B200 M3. Cisco UCS B200 M3 28 páginas. Blade server
Também para Cisco UCS B200 M3: Manual de instalação (34 páginas), Nota de instalação e manutenção (36 páginas), Nota de instalação e manutenção (37 páginas), Manual (8 páginas), Upgrade Manual (21 páginas)
Internal Components
Figure 9: Inside View of the B200 M3 Blade Server
1
3
5
7
Diagnostics Button and LEDs
At blade start-up, POST diagnostics test the CPUs, DIMMs, HDDs, and rear mezzanine modules, and any failure notifications are
sent to Cisco UCS Manager. You can view these notifications in the Cisco UCS Manager System Error Log or in the output of the
show tech-support command. If errors are found, an amber diagnostic LED also lights up next to the failed component. During run
time, the blade BIOS and component drivers monitor for hardware faults and will light up the amber diagnostic LED as needed.
LED states are saved, and if you remove the blade from the chassis the LED values will persist for up to 10 minutes. Pressing the
LED diagnostics button on the motherboard causes the LEDs that currently show a component fault to light for up to 30 seconds for
easier component identification. LED fault values are reset when the blade is reinserted into the chassis and booted, and the process
begins from its start.
If DIMM insertion errors are detected, they may cause the blade discovery process to fail and errors will be reported in the server
POST information, which is viewable using the UCS Manager GUI or CLI. DIMMs must be populated according to specific rules.
The rules depend on the blade server model. Refer to the documentation for a specific blade server for those rules.
Faults on the DIMMs or rear mezzanine modules also cause the server health LED to light solid amber for minor error conditions or
blinking amber for critical error conditions.
Hard drive bays
Battery
DIMM slots
Modular LOM (shown installed)
2
4
6
8
Internal USB connector
Cisco UCS-USBFLSH-S-4GB=
is recommended, but if another
USB drive will be used it must
be no wider than .8 inches, and
no more than 1.345 inches long
in order tp provide needed
clearances to install or remove
the USB drive.
CPU and heat sink
Diagnostic button
Adapter card connector
(Adapter not shown installed)
11