Upon completion of EndInsertion
The data format
is illegal
method, the following retune values
are set:
RC: OPOS_SUCCESS
RCE: 0
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_EXTENDED
RCE: OPOS_EMICR_CHECKDIGIT
A part of the
Upon completion of EndInsertion
data
is
not
method, the following retune values
analyzable
are set:
Or
RC: OPOS_SUCCESS
Noise error is
RCE: 0
occurred
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_EXTENDED
RCE: OPOS_EMICR_BADDATA
Upon completion of EndInsertion
The
cover
is
opened
during
method, the following retune values
insertion
are set:
RC: OPOS_SUCCESS
RCE: 0
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_EXTENDED
RCE: OPOS_EMICR_COVEROPEN
Upon completion of EndInsertion
The
paper
is
method, the following retune values
jammed
during
insertion
are set:
RC: OPOS_SUCCESS
RCE: 0
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_EXTENDED
RCE: OPOS_EMICR_JAM
27
APPLICATION DEVELOPMENT GUIDE
MICR (EPSON TM Series)
Version 3.00 Feb. 2019
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_SUCCESS
RCE: 0
When "Fire ErrorEvent on check
digit parity error" check box in
"Device Specific Setting" dialog is
marked , the result of data analysis
is notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_ILLEGAL
RCE: OPOS_EMICR_DIGITERROR
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_E_ILLEGAL
RCE: OPOS_EMICR_BADDATA
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_ILLEGAL
RCE: OPOS_EMICR_DATAERROR
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_E_OFFLINE
RCE: 0
There is no notification by event.
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_E_OFFLINE