aculab MC3 Manual de instalação - Página 15

Procurar online ou descarregar pdf Manual de instalação para Placa PCI aculab MC3. aculab MC3 19 páginas.

Appendix C: European Union countries

Service Requirements
In case of equipment malfunction, all repairs should be carried out by Aculab plc. It is the
responsibility of users requiring service to report the need for service to our company.
Service can be obtained at :
EN55022 declaration
This is a class B product. In a domestic environment, this product may cause radio interference
in which case the user may be required to take adequate measures.
No changes or modification to the MC3 PCI card is allowed without explicit written permission
from Aculab, as these could void the end user's authority to operate the device.
Safety Warnings
Interconnection circuits should be such that the equipment continues to comply with the
requirements of 2.3 of EN 60950 for SELV circuits, after making connections between circuits
using any of the internal ports.
Installation and Safety
The following information regarding installation is provided for guidance only and does not
eliminate the need for competence on the part of the installer.
The card must be installed such that with the exception of the PCI bus and H.100 connections,
clearance and creepage distances shown in the table below are maintained between the MC3
PCI card and any parts of the host PC or other expansion cards which use or generate a voltage
shown in the following table.
Clearance mm
2.0
2.6
4.0
4.0
For a host or other expansion card fitted in the host,
using or generating voltages greater than 300V (rms
or dc), advice from a competent
telecommunications safety engineer must be
obtained before installation of the relevant
equipment.
Clearance distances refer to the shortest distance between parts, measured through air. Creepage
distances refer to total distances measured across surfaces when installed in a normal office
environment. The creepage distances in parenthesis apply where the local environment within
the PC is subject to conductive pollution or dry non-conductive pollution that could become
conductive due to condensation.
Aculab plc
Unit 4, Bramley Road
Milton Keynes
MK1 1PT
UK
Phone
: +44 1908 273800
Fax
: +44 1908 273801
E-mail
Creepage mm
2.4 (3.8)
3.0 (4.8)
5.0 (8.0)
6.4 (10.0)
MC3 PCI Card Installation Guide
Voltage present on other parts of the
host or on expansion cards.
Up to 50V rms or dc
Up to 125V rms or dc
Up to 250V rms or dc
Up to 300V rms or dc
Above 300Vrms or Vdc
15