GUIDELINES FOR TORQUE-ARM REDUCER
LONG-TERM STORAGE
During periods of long storage, or when waiting for delivery or
installation of other equipment, special care should be taken to
protect a gear reducer to have it ready to be in the best condition
when placed into service.
By taking special precautions, problems such as seal leakage
and
reducer failure due to lack of lubrication, improper
lubrication quantity, or contamination can be avoided. The
following precautions will protect gear reducers during periods
of extended storage:
Preparation:
1.
Drain the oil from the unit. Add a vapor phase corrosion
inhibiting oil (VCI-105 oil by Daubert Chemical Co.) in
accordance with Table 4.
2.
Seal the unit air tight. Replace the vent plug with a standard
pipe plug and wire the vent to the unit.
3.
Cover the shaft extension with a waxy rust preventative,
compound that will keep oxygen away from the bare metal.
(Non-Rust X-110 by Daubert Chemical Co.)
4.
The instruction manuals and lubrication tags are paper and
must be kept dry. Either remove these documents and store
them inside or cover the unit with a durable waterproof cover
which can keep moisture away.
5.
Protect the reducer from dust, moisture, and other
contaminants by storing the unit in a dry area.
6.
In damp environments, the reducer should be packed inside
a moisture-proof container or an envelope of polyethylene
containing a desiccant material. If the reducer is to be stored
outdoors, cover the entire exterior with a rust preventative.
When Placing the Reducer Into Service:
1.
Assemble the vent plug into the proper hole.
2.
Clean the shaft extensions with petroleum solvents.
3.
Fill the unit to the proper oil level using a recommended
lubricant. VCI oil will not affect the new lubricant.
4.
Follow the installation instructions provided in this manual.
Table 4 - Quantity of VCI #105 Oil
Case Size
HSCXT3A-6B
HSCXT4A-6B
HSCXT5A-6B
HSCXT6-6B
HSCXT7-6B
VCI #105 & #10 are interchangeable
VCI #105 is more readily available
5
Quarts or Liters
.1
.2
.3
.4
.5