ECI 1000-U LCD Manual de instalação - Página 7

Procurar online ou descarregar pdf Manual de instalação para Controlador ECI 1000-U LCD. ECI 1000-U LCD 18 páginas.

5 Introduction

This manual is intended to help facilitate the installation of ECI 1000U LCD Door Operator board made
by Electronic Controls, Inc. The audience of the material included in this manual is for the certified
installation personnel. The ECI 1000U LCD control board complies with modern performance
specifications and meets or exceeds code requirements. Installation and adjustments must meet local,
state and national codes.

6 System Overview

The ECI 1000U LCD door controlled is a microprocessor-based board that controls all aspects of the door
motion including direction, velocity, deceleration and force.
The ECI 1000U LCD replaces the Elevator Components Industries 1001-1300, 1000-500 and 1000-1400
door controls boards.
The motor controller is a unique design for simple installation and reliable performance. It provides for
total control and adjustment through the entire door cycle and includes nudging. The door are held under
power while standing closed, running and while standing open. There are no potentiometers to adjust
speeds. All adjustments are performed by changing settings displayed on the LCD screen.

6.1 Electrical

120VAC single phase
48VDC motor output
Controller interface signals 120VAC/VDC or 24VDC

6.1.1 Fuses

F1 – 250V/3A AGC
F2 – 250V/2A AGC
F3 – 250V/9A GBB

6.2 Connections

6.2.1 X12 Power connection

L1A – AC neutral
L2A – AC hot

6.2.2 X11 connections

24B – 24VDC power input for 24VDC controller interface levels. For 120VAC controller this
input is tied directly to F1 of X11
F1 – Fused L2A (3A fuse)
COM – 24VDC return from controller power source. For 120VAC controller voltages this input
is tied directly to L1A of X11
L1A – unfused L1A
24B2 -
ECI 1000-U LCD Installation Manual
Electronic Controls, Inc.
7073 North Atlantic Ave. Cape Canaveral, FL 32920
800-633-9788
www.eciamerica.com
P a g e