12. WATER VALVE
•
To access the Water Valve, first remove the Toe Kick (see Section 10) and the Door Extension (see Section 11) (Fig. 12-1). The
Water Valve is held in place with two (2) Phillips screws (Fig. 12-2), remove the two screws and the Valve can be easily accessed.
TECH NOTE: A new Valve Hose Clamp (Fig. 12-3) is included with the replacement Water Valve, but the old Clamp can be
reused if carefully removed.
REPAIR MANUAL
Fig. 12-2
L 63 / LL 64 / LL 65
LI 640 / LI 670 / LI 700
Fig. 12-1
Fig. 12-3