Afterglow FW-CTGSQFP Manual - Página 14
Procurar online ou descarregar pdf Manual para Lareira exterior Afterglow FW-CTGSQFP. Afterglow FW-CTGSQFP 17 páginas. Cottage 34 in square gas fire pit
gas valve-hose connection (Figure 21)
To perform a leak test:
Make 2~3 oz. of leak solution by mixing one part liquid dishwashing detergent and three parts water. Noted:
1.
make sure control knob is "OFF".
Apply several drops of solution where the cylinder attaches to regulator (see Figure 19), inspect the solution
2.
at the connection looking for bubbles. If NO bubbles appear, the connection is secure. If bubbles appear, the
connection has the leak, disconnect the regulator, reconnect, perform another leak check. If you continue to
see bubbles after several attempts, cylinder valve is defective and should be returned to cylinder's supplier.
3.
Apply several drops of solution where gas valve attaches to bellows (see Figure 20), where gas valve
attaches to hose (see Figure 21), and where inlet tube attaches to bellows (see Figure 22). If NO bubbles
appear, the connections are secure. If bubbles appear, the connection has the leak, disconnect,
reconnect,perform another leak check. If you continue to see bubbles after several attempts, the part is
defective and should replace the part.
1. Push in gas control knob slightly and turn to "OFF".
2. Turn gas control knob the "ON/MIN".
3. Push in gas control knob all the way and hold. Continue to press the ignition button for 15 seconds.
4. If the burner does not light in 15 seconds, release the knob and it will pop back out. Wait 5 minutes before
attempting to light the burner again, repeat step 1 to 3.
1. Push in gas control knob slightly and turn to "OFF".
WARNING: For your safety, read and follow the Lighting Instructions in this manual and in the Rating Plate on
the appliance. IMPROPER LIGHTING PROCEDURES COULD RESULT IN A FIRE HAZARD OR
EXPLOSION HAZARD OR PROPERTY DAMAGE, INJURY OR LOSS OF LIFE.
LIGHTING INSTRUCTIONS
TO TURN OFF GAS
LIGHTING INSTRUCTIONS
1. Push in gas control knob slightly and
turn to "OFF".
2. Turn gas control knob to "ON/MIN".
3. Push in gas control knob all the way
and hold. Continue to press the
ignition button for 15 seconds.
ON/MIN
4. If the burner does not light in 15
(ENC./MÍN.)
seconds, release the knob and it will
pop back out. Wait 5 minutes before attempting
to light the burner again, repeat step 1 to 3.
TO TURN OFF GAS
1. Push in gas control knob slightly and turn to "OFF".
INSTRUCCIONES DE ENCENDIDO
1. Presione ligeramente la perilla de control del gas y gírela a la
posición "APG" (apagado).
2. Gire la perilla de control del gas a "ENC/MÍN" (encendido/mínimo).
3. Presione la perilla de control del gas hasta el fondo y mantenga presionada.
Siga presionando el botón de encendido durante 15 segundos.
4. Si el quemador no se enciende en 15 segundos, suelte la perilla y esta
volverá a su posición hacia afuera. Espere 5 minutos antes de intentar
encender el quemador nuevamente, repita los pasos 1 al 3.
PARA CERRAR EL GAS
1. Presion ligeramente la perilla de control del gas y gírela a la
posición "APG" (apagado)
inlet tube-bellows connection (Figure 22)
OFF (AP G.)
gas control knob
ignition button
M A X
( M Á X . )
1 AAA
IGNITOR
1.5V
( Encendedor )
Figure 23
14