ARO 650684 Series Manual do operador - Página 2
Procurar online ou descarregar pdf Manual do operador para Bomba de água ARO 650684 Series. ARO 650684 Series 2 páginas. Two-ball pump series
650684- X X X
Packing Material
Spring Arrangement
Plunger Type
GENERAL DESCRIPTION
The two-ball pumps are primarily designed for the pumping of
medium viscosity fl uids. Stainless steel construction off ers compat-
ibility with a wide range of fluids. The two-ball design provides
better priming of the lower foot valve. The double acting feature
is standard in all ARO industrial pumps. Material is delivered to the
pump discharge outlet on both the up and down stroke.
The motor is connected to the lower pump end by a spacer section.
This allows for lubrication of the upper packing gland and prevents
motor contamination because of normal wear and eventual leak-
age through the material packing gland. Be sure the solvent cup is
adequately fi lled with lubricant to protect the upper packings and
insure longest service life.
HAZARDOUS PRESSURE. Do not exceed maxi-
WARNING
mum operating pressure of 5459 p.s.i. (376.5 bar) at 120
p.s.i. (8.3 bar) inlet air pressure.
Pump Ratio X
Inlet Pressure to Pump Motor
Pump ratio is an expression of the relationship between the pump motor area
and the lower pump end area. EXAMPLE: When 150 p.s.i. (10.3 bar) inlet pressure
is supplied to the motor of a 4:1 ratio pump, it will develop a maximum of 600
p.s.i. (41.4 bar) fl uid pressure (at no fl ow) - as the fl uid control is opened, the fl ow
rate will increase as the motor cycle rate increases to keep up with the demand.
Refer to general information sheet for additional
WARNING
safety precautions and important information.
NOTICE: Thermal expansion can occur when the fl uid in the mate-
rial lines is exposed to elevated temperatures. Example: Material
lines located in a non-insulated roof area can warm due to sunlight.
Install a pressure relief valve in the pumping system.
Replacement warning label (pn 92325) is available upon re-
quest.
TROUBLE SHOOTING
Pump problems can occur in either the air motor section or the
lower pump end section. Use these basic guidelines to help deter-
mine which section is aff ected.
Pump will not cycle.
Be certain to first check for non-pump problems including
kinked, restrictive or plugged inlet / outlet hose or dispensing
device. Depressurize the pump system and clean out any ob-
structions in the inlet / outlet material lines.
Refer to the motor manual for trouble shooting if the pump
does not cycle and / or air leaks from the air motor.
Damaged motor. Service the motor.
Pump cycles but does not deliver material.
Refer to the lower pump end manual for further trouble shoot-
ing.
Page 2 of 2
PUMP OPTION DESCRIPTION CHART
PACKING MATERIAL
3 - Glass fi lled PTFE
C - UHMW-PE
G - UHMW-PE / Leather staggered
SPRING ARRANGEMENT
4 - Multiple wave spring with stainless
steel balls
7 - Multiple wave spring with alternate
balls (hard stainless steel)
=
Maximum Pump
Fluid Pressure
(Packings are upper and lower unless noted)
P - UHMW-PE / Glass fi lled PTFE staggered (upper)
UHMW-PE (lower)
R - Glass fi lled PTFE / UHMW-PE staggered (upper)
Glass fi lled PTFE (lower)
PLUNGER TYPE
3 - Hard stainless steel with hard chrome plating
B - Hard stainless steel with ceramic coating
PUMP CONNECTION - UPPER / LOWER
NOTE: All threads are right hand.
1.
Lay the pump assembly on a work bench.
2.
Remove the three (Y85-29-C) nuts from the three spacer rods
(see fi gure 1).
3.
Pull the air motor from the lower pump end until the motor
piston rod is in the "down" position and the lower pump end
rod is in the "up" position.
4.
Using e-ring pliers, slide the retaining ring up far enough to
allow the sleeve to move upward and release the two connec-
tors (see fi gure 2).
PUMP CONNECTION DETAIL
REASSEMBLY
1.
Align the pump motor with the lower pump end. Position the
air inlet of the motor 59° from the material outlet.
2.
Install the two (90096) connectors and retain with the (90109)
sleeve. Slide the (90102) retaining ring back into position.
3.
Reinstall the spacer rods to the pump motor.
4.
Bring the motor and lower pump together and retain with
three (Y85-29-C) nuts.
ARO® is a registered trademark of Ingersoll-Rand Company
Pump Motor Piston Rod
90102 Retaining Ring
90109 Sleeve
90096 Connector (2)
Lower Pump Piston Rod
Figure 2
PN 97999-656
650684-XXX (en)