Artison Sound Surface 40 Manual de instalação - Página 3

Procurar online ou descarregar pdf Manual de instalação para Altifalantes Artison Sound Surface 40. Artison Sound Surface 40 11 páginas. Invisible speaker

Pre Construction Bracket Install
The Artison Sound Surface 40 and Sound Surface 80 speakers are designed to be installed into a wall
or ceiling. Once installed, the face of the speaker is then sheetrock mudded so the complete speaker is
embedded into the wall and can't be seen. Installation of the speaker varies slightly depending on whether
the install is done during initial construction or retrofitted after the drywall is already hung. Both installations
are described below:
– For NEW CONSTRUCTION, follow the steps in section 1 -
construction bracket is installed, skip to section 4
– For RETROFIT INSTALLATIONS, skip section 1 and start with section 2 -

1) Pre-Construction Bracket Installation

A Sound Surface Pre-construction bracket (SURFACE-1PCB-00) is available for installs where the wall
board is not installed.
The pre-construction bracket is installed onto existing studs and will reserve an opening during the
rough stage so the drywall can be installed around it.
Pre-construction brackets (sold separately) are available for stud and joist openings that are either 12
or 16 inch on center.
With the use of the Pre-construction bracket, a smaller cavity can be used. The clearances required
for this installation are: (9
The pre-construction bracket can be used for installations that include either
drywall. With rubber spacers installed,
drywall can be used.
Follow instructions below to install Pre-construction bracket:
½
1.
When
inch drywall is being installed, remove the
rubber spacers from the rear of the bracket.
When
inch wall board is being installed, leave the
rubber spacers intact.
HELPFUL! The face of the bracket should be slightly
inset from the edge of the drywall. This allows for
joint compound to be spread over bracket to cre-
ate a level surface.
2. Attach the bracket to the wall studs or ceiling
joists using the (5) pre-drilled countersunk holes
positioned along the outside edge of the bracket.
See Figure 1.
TIP! Use mounting screws (not provided) appropriate
for the stud or joist type: wood, metal, etc.
3. After bracket is installed, proceed to section 4 -
Attach
Handle. Skip the retrofit instructions on page
4 if this is new construction.
Surface 40/80 Speakers | 009-1656-01 | 180731
Copyright 2018 Savant Systems, LLC
Attach Handle
1
1
3 /
/
in x 23
in x 3
/
4
2
8
inch drywall can be used. With spacers removed,
3 of 11
Pre Construction Bracket
Mark the Wall/Ceiling
in) (248 mm x 597 mm x 80 mm) deep.
Figure 1.
45 Perseverance Way, Hyannis, MA 02601
Savant.com
Installation. After pre-
½
inch or
inch
½
inch
| 508.683.2500