(SYMPTOM: System regularly displays "Low Pressure" error when using 3 heads)
1) Follow Removal Procedure steps 1-4.
2) Connect the unit to power source
3) Locate the pressure switch
4) The number to the lower right should read 20.0. If yes, proceed to step 5. If the number reads
25.0, press the SET button once. 20.0 should now appear.
5) When 20.0 appears, press the down arrow button multiple times until the sensor screen shows
15.0
6) Unplug unit from power source
7) Follow Reassembly Steps
(SYMPTOM: Fog plume from head(s), ADP or APA is weak/inconsistent)
While several issues can contribute to a weak fog plume including a pump issue, there may be
residue build-up in the head(s). Clean the mounted and APA heads as follows:
1) Carefully remove head using a wrench or pliers turning counter clockwise. Remove the red O-
ring and white plastic washer located on the nozzle base. Do not lose the O-ring or washer!
2) Using two sets of wrenches or pliers, carefully disassemble the nozzle by holding the base
while twisting the top section of the nozzle counter clockwise.
3) Once disassembled, remove the internal diffuser cap.
4) Soak the 3 nozzle pieces in hot water for 15 minutes. Use a soft brush to make sure any
deposits are removed from the surfaces.
5) Reassemble the nozzle in reverse order. Don't forget to reattach the O-ring and washer.
6) NOTE: DO NOT OVERTIGHTEN ANY OF THESE COMPONENTS! Light 1/8-1/4 turn is
generally sufficient to establish the necessary seal.
Rev 3.21
Pressure Sensor Adjustment*
* Some configurations do not include pressure sensors
Nozzle Cleaning Procedure
4