• POWER:

Make sure the Main on/off switch is set to the "0" position. Connect your
Power Cord to the Power Receptacle on the back of the Vacuum Sealer
and to a Standard 120 Volt A.C. outlet (or to a 220-240 Volt A.C. outlet if
your unit is made for this higher voltage – See serial number tag next to
the Power Receptacle of your Sealer to confirm)

• AIR:

Connect the supplied push fitting-1/4" Thread adaptor to your compressed
air source. Then use the supplied ¼" tubing to connect between the fitting
on your Vacuum Sealer (labeled "AIR") and to the compressed air source.
Please be careful when adding air pressure to the Vacuum Sealer as the
bar will quickly rise. Please use clean dry air only to keep your sealer's
internal components working for years to come. The Vacuum Sealer
requires a constant air pressure between 100 to 110 psi.
SETTING THE SEAL PART OF YOUR AMERIVACS
RETRACTABLE NOZZLE VACUUM SEALER
1. Turn on your Vacuum Sealer by pressing the main On/Off (I/0) switch.
2. Set Heat Timer to four (4) seconds and Cool Timer to six (6).
3. Take one bag and fold it in half. Place your folded bag between the jaws
back enough to extend past the Pressure Bar. Placing it above, below or
to one side of the nozzle is ok.
4. Hold bag taut on the
sides close to the front of
the Pressure bar (to
avoid any wrinkles in
your seal), and keeping
fingers away from the
Sealing Jaws, press Foot
Switch long enough so
that the Pressure Bar
closes, then release; The
Nozzle will retract, the
Pressure Bar will close
tighter and the bag will
be heat sealed as indicated by the LED lights on the Heat and Cool
Timers then, the Pressure Bar will rise, releasing your bag and the nozzle
will slowly extend outward, ready for the next cycle.