5.1.4
View in bus connecting box DeviceNet [A]
Terminal assignment
DRAIN Shield
GND
UB
CAN_H CAN bus signal (dominant HIGH)
CAN_L CAN bus signal (dominant LOW)
Terminals of the same signiicance are internally connected and identical in their
i
functions� Max� load on the internal terminal connections UB-UB and GND-GND
is 1 A each�
5.1.5
Setting for the terminating resistors
ON = Last user
OFF = User x
5.1.6
Setting for the user address
Address can be set by rotary switches� Example: User address 23
MB252EN - 11173969, 16A1, Baumer_HMG10-DeviceNet_II_EN
Ground for UB
Voltage supply 10���30 VDC
ELECTRICAL CONNECTION / DEVICENET
Setting for the terminating resistors
Setting for the transmission rate
Setting for the user address