Baumer Hubner Berlin PMG 10 Руководство по установке и эксплуатации - Страница 10
Просмотреть онлайн или скачать pdf Руководство по установке и эксплуатации для Медиаконвертер Baumer Hubner Berlin PMG 10. Baumer Hubner Berlin PMG 10 36 страниц. Absolute encoder with magnetic sensing
Также для Baumer Hubner Berlin PMG 10: Руководство по установке и эксплуатации (48 страниц)
MOUNTING / MOUNTING WITH EURO FLANGE B10
4.
MOUNTING
4.1
Mounting with EURO flange B10
4.1.1
Mounting the spring disk coupling to the encoder
We recommend using the Baumer Hübner spring disk coupling K 35, see
page
11, available as accessory� When other couplings are used pay attention to
manufacturer's notes�
4.1.2
Mounting to drive shaft
)
Lifetime restrictions and angle error by radial deviations
High runout of the drive shaft can cause encoder angle error�
High runout of the drive shaft can cause vibrations, which can shorten the lifeti-
me of the encoder�
» Lubricate drive shaft!
» Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
i
The encoder must be mounted with cable connection facing downward and not
exposed to water�
7/33
2�5 mm
7
M
= 100 Ncm
t
9
10 mm
8
MB245EN - 11171693, 17A2, Baumer_PMG10-SSI_II_EN
section 4.3,