Follett H50R5A/W Руководство по установке - Страница 5

Просмотреть онлайн или скачать pdf Руководство по установке для Диспенсер для воды Follett H50R5A/W. Follett H50R5A/W 13 страниц. Ice and water dispenser
Также для Follett H50R5A/W: Руководство по эксплуатации, обслуживанию и запчастям (17 страниц)

Installation procedures

• All dispensers must be installed level in both directions to ensure proper operation.
• Required service and ventilation clearances:
• Models with integral icemakers (in top of cabinet) — 6" (15.2 cm) on right side of dispenser and at top.
• Models with remote icemakers — 12" (30.5 cm) at top.
• Freestanding models — 12" (30.5 cm) at top and 4" (10.2 cm) at back.
• All countertop and wallhung dispensers provide the option of taking utilities out the bottom or back of the
dispenser. See counter cut-out drawings for bottom exiting utilities on units with and without drain pans. For
installations where utilities will exit through back of dispenser, refer to back view drawings.
• Wallhung models are designed for use above sinks or custom drain pans and are not normally equipped
with integral drain pans. (Center of sink should be 19.5" (49.5 cm) from back wall.) Connection of utilities through
the back for wallhung units is the same as shown in drawings for countertop models except that the 3.25" (8.3 cm)
high drain pan is absent.

Installing freestanding dispensers

Do NOT tilt unit further
!
than 30° off vertical.
1. Carefully tip dispenser back to
expose underside and block up in
place.
2. Remove legs from shipping box
(taped to drain pan of dispenser) and
screw into dispenser bottom, taking
care to seat legs securely against
underside of dispenser.
3. Position unit in desired location and
adjust bullets on legs to level in both
directions.
4. Remove front cover of base section
and unblock shipping tie-down
securing icemaker to dispenser base.
5. Make final connections.
Note: Electrical connection box can
also be accessed through front of
dispenser by removing front cover,
black plastic chute cover and
stainless splash panel.

Before you begin

electrical
Shaded
connection
areas
box
indicate
internal
connections
38"
96.5 cm
34"
86.4 cm
28.5"
72.4 cm
9.25"
23.5 cm
3/8" FPT
icemaker drain
(air cooled only)
Rear connections — Freestanding models
3
access
panel
18.125"
46 cm
electrical entrance
3/4" FPT
3/8" FPT
dispenser drain
water inlet
1/2" FPT
condenser
drain (water
cooled only)
9.75"
10"
24.8 cm
25.4 cm
3/8" FPT
icemaker drain
(water cooled only)
ICDI220
10.5" (26.7 cm)
5.5" (14 cm)
3/8" FPT
condenser inlet
(water cooled only)
3.5"
8.9 cm
15"
38.1 cm