5.3 Periodic maintenance

Disconnect the power supply before performing any service or maintenance on the unit. Failure
to do so may result in serious injury or death.
Depending on how often the COOL-SPACE
performed anywhere from every week for heavy use to monthly for light use. Shut down the
unit and drain the water sump. The cooling pads act as a filtering agent and remove dust
and other particles from the incoming air stream. These particles will flow into the sump and
collect there. Also, impurities in the water will collect in the sump.
1. Close the water flow valve and open the drain valve.
2. Run pump until sump is dry then immediately shut off pump.
3. Turn unit off and disconnect the power supply.
4. Remove cooling pads, refer to section 5.1.
5. Clean out reservoir with either a towel or wet/dry vacuum.
6. Check belt for tightness, if applicable.
7. Remove the water spray bar and its plug. Insure holes are free of debris.
8. Reinstall pads and pad retainer.
9. Reinstall rear guard (if applicable).
To keep the COOL-SPACE
are kept clean and dust-free. Dust and other particles have an adverse effect on the
media's ability to introduce water into the air stream. If the pad surface becomes dirty or
dusty, clean with a soft brush and water.
The fan motor may require periodic lubrication depending on the COOL-SPACE
Check your model for an oil fill location on the motor. A few drops of light oil each year will
extend motor life.

5.4 Storage

1. Remove the pads, as described in section 5.1
2. Clean with a soft brush and water to remove dust and debris
3. Drain sump using procedure described in section 5.3 and wipe dry
4. Store the COOL-SPACE
build-up. Covers for your unit can be found online at
ELECTRICAL SHOCK HAZARD
®
unit operates, this procedure should be
Draining the Water Sump
®
unit operating at peak efficiency, ensure that the cooling pads
®
unit in a dry area and cover if possible to prevent dust
5
®
www.cool-space.com
model.