Pump Storage
It is important to comply with the recommendations for storage in the operator's manual of the machine
into which the pump is incorporated.
For the pump itself, at the end of pumping operations it is essential to flush out the internal circuit by pump
ing clean water. After this, open the intake circuit to the air and leave the pump in operation until the internal
circuit is completely empty. Following this simple procedure at the end of every operating session will prevent
the retention inside the pump of products which are often corrosive and may damage its liquid circuit over
the long-term.
If the pump is in storage during the winter in locations with severe weather conditions, it is very important to
flush out the internal circuit as described above and then fill the pump with A/R Pump Saver, AR64511. Then
take care to drain the liquid from the system and the pump.
Putting the pump back into service
Before putting the pump back into service after storage, check the oil level and the tightness of the
mounting screws.
Scrapping the pump
Used units must be disposed of in compliance with local legislation.
A/R Pump Saver
P/N 64511
Protects Pumps from Freezing Conditions