Anywire ARW-03 Руководство по эксплуатации - Страница 12
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Привод Blu-ray Anywire ARW-03. Anywire ARW-03 17 страниц. Address writer
Также для Anywire ARW-03: Руководство по эксплуатации системы (6 страниц)
[Parameters]
Parameter consists of the movement element and the
variable built in a unit.
For a type of unit to select parameters, select and set the
movement specification in ARW-03.
The following parameters are available depending on models.
■Parameters of representative models
Type
Door type
fall-proof
Small-sized
fall-proof
ASLINKER
ASLINKAMP
For details of the parameter, also refer to the instruction manual of each unit.
Model
A027XB-F02□-P
A227XB-F02□-P
A027XB-K02VN-P
A027XB-K02V-P
A227XB-K02VN-P
A227XB-K02V-P
B280SB-02U□-C1220
B280PB-02U□-C1220
B281□B-02U□-CC20
B289SB-01AF-CAM20
B289SB-01AF-CAS
B289SB-01AP-CAM20
B289SB-01AP-CAS
!
variable values. This may cause the writer to malfunction.
If you try to set a value that exceeds the parameters and
variable values, "E-303" is displayed in the display portion
of ARW-03.
Details of parameter
01
1, 2, 3, 4, 5, 6, 7
02
1, 2, 3, 4, 5, 6, 7
03
1, 2, 3, 4, 5, 6, 7, 8, 9, 10
04
0 (green), 1 (red), 2 (blue), 3 (yellow), 4 (sky-blue),
5 (purple) and 6 (white)
05
-
06
-
0 (green), 1 (red), 2 (blue), 3 (yellow), 4 (sky-blue),
01
5 (purple) and 6 (white)
02
-
03
-
04
-
05
-
06
-
0 (I/O disconnection, 24VL short-circuit detection: OFF)
01
1 (I/O disconnection, 24VL short-circuit detection: ON)
0 (I/O disconnection, 24VL short-circuit detection: OFF)
01
1 (I/O disconnection, 24VL short-circuit detection: ON)
Setting of sensor sensitivity (threshold)
01
Adjustment range: 0 – 100 (Before shipment: 50)
Hysteresis setting for sensor sensitivity
02
Adjustment range: 0 – 100 (Before shipment: 5)
Setting of upper limit of alarm judgment value
03
Adjustment range: 0 – 100 (Before shipment: 80)
Setting of lower limit of alarm judgment value
04
Adjustment range: 0 – 100 (Before shipment: 20)
Setting of monitoring time in alarm judgment value
05
Adjustment range: 3 – 255 (Before shipment: 50) (Unit: 0.1 sec)
Switching of Dark ON and Light ON, Before shipment: 0
Dark (shielding) ON: 0
Transmission-
06
type
Light (Transmission) ON: 1
Dark (without reflection) ON: 0
Reflection-
type
Light (with reflection) ON: 1
Setting of operating mode
07
0 (Diagnosis function: OFF)
1 (Diagnosis function: ON)
Internal setting for photoelectric head
Variable: 0-3, Before shipment: 0
08
*This value is used for setting before shipment.
If changing this value, consult our Sales Division.
-ARW03 12/17-
Do not operate the writer with a value that
CAUTION
exceeds the following parameters or
*7 or more cannot be set.
*7 or more cannot be set.
*ASLINKAMP-side display interlock
Door upper position
Door lower position
Timer
Display colors
Reserve
Reserve
Display colors
Reserve
Reserve
Reserve
Reserve
Reserve
Function
Selection
Function
Selection
Function
Selection
Function
Selection
Function
Selection
Function
Selection
Function
Selection
Function
Selection
Function
Selection
Function
Selection