Anypos
Point of Service
Clear and Calibration
Press this button to erase the 25 points calibration/linearization parameters
and force user to do 4 points calibration again. After 25 points calibration
data was clear, the 4 points calibration data will be invalid. It needs to do 4
points calibration.
Linearization
Linearization ( 25 or 9 points calibration ) function is used to compensate
the touchscreen linearity. After linearization completed, the linearity of the
touchscreen will be shown in the Linearity curve window.
Pressing this button, a new window will be popped-up at the location when
the touchscreen was mapped to area for this touch system to guide the user
do 25 points calibration. User should follows the guide to touch and hold
the blinking X symbol in the calibration window until it does not blink to
make sure that the utility can gather enough data for computation.