Danish Interpretation Systems DCS 6000 Руководство пользователя - Страница 15

Просмотреть онлайн или скачать pdf Руководство пользователя для Конференц-система Danish Interpretation Systems DCS 6000. Danish Interpretation Systems DCS 6000 19 страниц. Digital conference system
Также для Danish Interpretation Systems DCS 6000: Руководство пользователя (10 страниц), Руководство пользователя (14 страниц), Руководство пользователя (14 страниц), Руководство пользователя (13 страниц), Руководство пользователя (18 страниц), Руководство пользователя (14 страниц)

DIS

Max. number of units to be connected

The following tables shows the maximum number of
units, which can be connected to a CU 6105 Central
Unit.
In the tables the 'Feeding Cable' is defined as the
cable between the EX 6010 and the first Conference
Unit and the 'Interconnecting Cable is defined as the
cable connecting two conference units.
The following tables show the maximum number of
units, which can be connected to each DCS-LAN chain
output
The same numbers are valid for the output of a PS
6000.
DC 6120 P, DC 6190 P, DM 6680 P
Conference Units
Length of
Length of inter
Feeding Cable
connecting
Type CAT5e
Cable, Type
AWG24
CAT5e AWG24
10 m
1 m
30 m
1 m
50 m
1 m
100 m
1 m
150 m
1 m
10 m
2 m
30 m
2 m
50 m
2 m
100 m
2 m
150 m
2 m
Figure 0-A
DC 6120 P, DC 6190 P or DM 6680 P
Conference Units connected
DC 6990 P Conference Unit
Length of
Length of inter
Feeding Cable
connecting
Type CAT5e
Cable, Type
AWG24
CAT5e AWG24
10 m
1 m
30 m
1 m
50 m
1 m
100 m
1 m
150 m
1 m
10 m
2 m
Total cable
Max. number
length
of units pr
output
51 m
42
67 m
38
83 m
34
122 m
23
165 m
16
88 m
40
98 m
35
108 m
30
140 m
21
178 m
15
Total cable
Max. number
length
of DC 6990 P
pr. output
35 m
26
53 m
24
70 m
21
112 m
13
158 m
9
56 m
25
User Manual EX 6010 rev F.doc
30 m
2 m
50 m
2 m
100 m
2 m
150 m
2 m
Figure 0-B
DC 6990 P Conference Units connected
CM/DM 6080 F / DM 6620 F
Chairman/Delegate
Length of
Length of inter
Feeding Cable
connecting
Type CAT5e
Cable, Type
AWG24
CAT5e AWG24
10 m
1 m
30 m
1 m
50 m
1 m
100 m
1 m
150 m
1 m
10 m
2 m
30 m
2 m
50 m
2 m
100 m
2 m
150 m
2 m
Figure 0-C
CM/DM 6080 F or DM 6620 F
Chairman/Delegate Units connected
CM/DM 6680 F Chairman/Delegate Units
connected
Length of
Length of inter
Feeding Cable
connecting
Type CAT5e
Cable, Type
AWG24
CAT5e AWG24
10 m
1 m
30 m
1 m
50 m
1 m
100 m
1 m
150 m
1 m
10 m
2 m
30 m
2 m
50 m
2 m
100 m
2 m
150 m
2 m
Figure 0-D
CM/DM 6680 F Chairman/Delegate Units
connected
User Manual
72 m
22
90 m
19
124 m
13
166 m
9
Total cable
Max. number
length
of DC 61xxP
pr. output
39 m
30
56 m
27
73 m
24
115 m
16
160 m
11
64 m
28
78 m
25
94 m
23
130 m
16
170 m
11
Total cable
Max. number
length
of DC 61xxP
pr. output
35 m
27
53 m
24
70 m
21
113 m
14
159 m
10
58 m
25
72 m
22
88 m
20
126 m
14
166 m
9
15