DANLERS CEFL PIR Краткое руководство по эксплуатации - Страница 2

Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Переключатель DANLERS CEFL PIR. DANLERS CEFL PIR 2 страницы. Ceiling flush mounted pir occupancy switch
Также для DANLERS CEFL PIR: Указания по установке (15 страниц)

DANLERS CEFL PIR Краткое руководство по эксплуатации
CEFL PIR
Ceiling Flush Mounted PIR Occupancy Switch
Input: 220-240 Vac 50Hz
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THE PRODUCT
Note 1: Optional manual
wall switch for overriding off.
L
230 VAC
N
N
L
SL
Note 1: Optional manual
DIAGRAM D (WIRING A SINGLE PIR)
wall switch for overriding off.
L
230 VAC
N
INPUT:
Voltage:
220 - 240Vac
Frequency:
50Hz
Max. mains current:
0.05A
N
L
SL
LOADING:
CEFL PIR
Resistive loads:
6 amps (1500W)
Fluorescent:
6 amps (1500W)
LED Drivers and LED
6 amps (1500W)
lamps and fittings:
Electronic and wire
3 amps (1500W)
wound transformer:
CFL and 2D lamps:
2 amps (500W)
Fans:
1 amp (250W)
2W resistive, suitable
for most energy
Minimum load
saving lamps, LEDs
and emergency
fittings.
OPERATING CONDITIONS:
The temperature difference between the
detection target and the background must
be at least 4 °C.
Ambient
-20... +40 °C (lout
temperature:
0.05 A)
PRECAUTIONS AND WARRANTY
This product conforms to BS EN 60669-2-1 and
BS EN 55015.
Please ensure the most recent edition of the
appropriate local wiring regulations are observed
and suitable protection is provided e.g. a 10 amp
circuit breaker and voltage surge protection.
Please ensure that this device is disconnected
from the supply if an insulation test is made.
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388 E-mail: [email protected]
www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
DAT0089 CEFLPIR
WIRING DIAGRAMS
Note 2:
Alternative
position for
optional
load
wall switch
CEFL PIR
TECHNICAL DETAILS
Max. case
Note 2:
temperature:
Alternative
Storage
position for
optional
temperature:
load
wall switch
Max. relative
N
L
SL
humidity:
CEFL PIR
CONNECTORS:
Terminal block
Wire size:
Wire strip length:
Tightening torque:
MECHANICAL DATA:
Dimensions:
Weight:
Degree of
protection:
Protection class:
Material (casing)
Finish / Colour
Protection class:
Other DANLERS Product ranges
- Remotely adjusted PIR occupancy switches
- Manually adjusted PIR occupancy switches
- Daylight linked dimming controls
- Photocell switches
- Time lag switches
- Outdoor security switches
- Dimmer switches inc. LED dimming
- HVAC controls
- Radio remote (RF) controls
Note 1: Optional manual
wall switch for overriding off.
L
230 VAC
N
N
L
SL
Note 1: Optional manual
wall switch for overriding off.
L
230 VAC
N
N
L
SL
CEFL PIR
DIAGRAM E (WIRING IN PIRS IN PARALLEL)
CONFORMITY AND STANDARDS:
+70 °C
EMC emission:
-25... +75 °C
EMC immunity:
0... 80%, non cond.
Safety:
0.5mm
- 2.5mm
2
2
Environment:
solid or stranded
6-7mm
VARIANTS - LOW VOLTAGE:
0,4 Nm/4 Kgf.cm
DANLERS also design and manufacture an
extensive range of Ceiling Flush Mounted
PIR Occupancy Switch variants some of
72mm x 72mm x
which are listed below:
68mm
CEFL PIR 12VAC
246g (unpacked)
CEFL PIR 12VDC
CEFL PIR 24VAC
CEFL PIR 24VDC
IP20
CEFL PIR 12VACVF
Built-in Class 2
CEFL PIR 12VDCVF
CEFL PIR 24VACVF
Flame-retardant
CEFL PIR 24VDCVF
polycarbonate
Matt /White (RAL
9003)
Built-in Class 2
Please call for more information or visit our website.
This product is covered by a warranty which
extends to 5 years from the date of manufacture.
MADE IN THE UK
(Presence detection)
Note 2:
Alternative
position for
optional
load
wall switch
CEFL PIR
Note 2:
Alternative
position for
optional
load
wall switch
N
L
SL
CEFL PIR
EN60669-2-1:2004
inc. A12:2010
EN60669-2-1:2004
inc. A12:2010
EN60669-2-1:2004
inc. A12:2010
Complies with
WEEE and RoHS
directives
12V or 24V (ac or
dc) operation
12V or 24V (ac or
dc) operation Volt
Free contacts
11/11/2020