3.4. Overview configuration parameters

Z-Wave products can be used directly after inclusion in the network. However, configuration settings
can be used to adapt the behavior of the device even better to the requirements of the application and
to activate additional functions.
Para-
Byte
meter
size
Threshold value
10
1
battery alarm
BASIC SET to
association
14
1
group 2 (motion
Invert value of
15
1
BASIC SET
command
32
1
Bypass function
Default value
Function
(default)
10
alarm)
Description
Percentage value from when the low battery
alarm should be transmitted.
Adjustable from 5 - 50 in percent
(Hexadecimal: 0x05 - 0x32)
BASIC SET should be sent after a motion
alarm.
0
0 = Disabled
1 = Active
(Hexadecimal: 0x00 - 0x01)
Set the value of the BASIC SET command for
movement alarm and acknowledgement.
0 = The motion alarm sends the BASIC
SET value "On" (0xFF), the
acknowledgement sends the BASIC SET
0
value "Off" (0x00)
1 = The motion alarm sends the BASIC
SET value "Off" (0x00), the
acknowledgement sends the BASIC SET
value "On" (0xFF)
(Hexadecimal: 0x00 - 0x01)
Enables or disables the bypass function.
0 = Bypass function activated
0
1 = Bypass function deactivated
(Hexadecimal: 0x00 - 0x01)
17