2.6.
Model iBoot-IO-LS 1410044
•
Default Power ON
•
DC Voltage (Wet) Control
iBoot-IO-LS
O
Feedback Output
G
Ground
I
Control Input
2.7.
Model iBoot-IO-OFFLS 1410045
•
Default Power OFF
•
DC Voltage (Wet) Control
iBoot-IO-OFFLS
O
Feedback Output
G
Ground
I
Control Input
Output Transistor Rating:
V181217N
Function
High(Open) = Power OFF,
Low (Ground) = Power ON
Common Ground
Open, <1.5 VDC Power ON
+3-12 VDC = Power OFF
Function
High(Open) = Power OFF,
Low (Ground) = Power ON
Common Ground
Open, <1.5 VDC Power ON
+3-12 VDC = Power OFF
100 mA 30 VDC Max.
iBoot-IO
Wiring Diagram for +VDC (Wet) Models
iBoot-IO-LS and iBoot-IO-OFFLS
Page 3