Austdac HUBBUS HBLTU Руководство пользователя - Страница 11

Просмотреть онлайн или скачать pdf Руководство пользователя для Сенсорные терминалы Austdac HUBBUS HBLTU. Austdac HUBBUS HBLTU 12 страниц. Termination unit

6 Terminals

6.1 TYPE

The PCB terminal connector is a Phoenix Contact style with 5.08mm pitch. Austdac
supplies the module with either a 90˚ free hanging push-in spring terminal plug.

6.2 LAYOUT

6.2.1 Termination Connection

If system termination is determined to be required, HubBus signal shall be
connected to the "Term 1" terminals; if no system termination is required, HubBus
signal shall be connected to the "No Term" terminals. "Term 2" and "Term 3"
terminals are not currently used but are provided for future development only.
WARNING:
The HubBus Signal –ve line must not be tied to any common, 0V, ground or
Earth points.
HubBus Line Termination Unit
HBLTU USER MANUAL

Figure 3: Terminal Plug

HBLTU
5
Sig +
6
Sig -
7
Sig +
8
Sig -

Table 1: HBLTU Terminals

11 OF 12
Sig +
1
Sig -
2
Sig +
3
Sig -
4
125-258-12
Issue: 01