NOTE: Entry of a number other than one specified will give unpredictable results.
For fields *43- *46: Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; #+15 for F. Enter [ ✱ ] as the fourth digit if a 3-digit account number (for 3+1 dialer
reporting format) is used. Enter 0 as the first digit of a 4-digit account number for Nos. 0000-0999. Exit field by pressing ✱ if only 3 digits are used. E.g., For Acct.
B234, enter:
#+11| 2 | 3 | 4
43 PARTITION 1 PRIMARY ACCT. No.
✱
✱
44 PART. 1 SECONDARY ACCT. No.
✱
45 PARTITION 2 PRIMARY ACCT. No.
46 PARTITION 2 SECONDARY ACCT.
✱
No.
47
✱
PHONE SYSTEM SELECT
48
✱
REPORT FORMAT
✱
49
SPLIT/DUAL REPORTING
50
✱
BURGLARY DIALER DELAY
✱ 53
SESCOA/RADIONICS SELECT
✱ 54
DYNAMIC SIGNALING DELAY
✱ 55
DYNAMIC SIGNALING PRIORITY
✱ 56, *57, *58
MENU MODES
TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES ( ✱ 59 – ✱ 76, & ✱ 89):
For 3+1 or 4+1 Standard Format: Enter a code in the first box: 1–9, #+10 for 0, #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15 for F.
A 0 ( not #+10) in the first box will disable a report. A 0 ( not #+10) in the second box will result in automatic advance to the next field.
For Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd digits) for 1–9, 0, or B–F, as described above.
A 0 ( not #+10) in the second box will eliminate the expanded message for that report. A 0 ( not #+10) in both boxes will disable the report.
For Ademco Contact ID® Reporting: Enter any digit (other than 0) in the first box, to enable zone to report (entries in the second boxes are ignored).
A 0 ( not #+10) in the first box disables the report.
SYSTEM STATUS REPORT CODES ( ✱ 59– ✱ 68)
✱ 59
EXIT ERROR REPORT CODE
✱ 60
TROUBLE REPORT CODE
✱ 61
BYPASS REPORT CODE
✱ 62
AC LOSS REPORT CODE
✱ 63
LOW BAT REPORT CODE
✱ 64
TEST REPORT CODE
Each mode sets schedule 32 (VISTA-20P) or
schedule 08 (VISTA-15P) to the stated
repeat option; first test report sent 12 hours after command.
www.PDF-Zoo.com
| | | /
| | | | |
| | | /
| | | | |
| | | /
| | | | |
| | | /
| | | | |
[1]
[77]
primary
secondary
[0]
[2]
[0]
[0]
[0]
These are Menu Mode commands, not data fields, for Zone Programming, Function
Key Programming, and Expert Mode Zone Programming respectively. See page 2 and
their respective sections in the Installation and Setup Guide for procedures.
UL: see installation instructions for requirements
[0]
See box above.
|
[00]
See box above.
|
[00]
See box above.
|
[00]
See box above.
|
[00]
See box above.
|
[00]
See box above. Use Scheduling mode to set periodic test reports,
or use the following key commands:
installer code +[#] + [0] + 0 = test report sent every 24 hours
installer code +[#] + [0] + 1 = test report sent once per week
installer code +[#] + [0] + 2 = test report sent every 28 days
– 4 –
Enter 4 or 10 digits, depending on selection in *48 Report
Format. See box above. To clear entries, press * 43 *. [FFFF]
Enter 4 or 10 digits, depending on selection in *48 Report
Format. See box above. To clear entries, press * 44 * . [FFFF]
Enter 4 or 10 digits, depending on selection in *48 Report
Format. See box above. To clear entries, press * 45 * . [FFFF]
Enter 4 or 10 digits, depending on selection in *48 Report
Format. See box above. To clear entries, press * 46 * . [FFFF]
If Cent. Sta. IS NOT on a WATS line:
0=Pulse Dial; 1=Tone Dial;
if Cent. Sta. IS on a WATS line:
2 = Pulse Dial ; 3 = Tone Dial
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
5 = 10-digit ADEMCO CONTACT ID® REPORTING
6 = 4+2 ADEMCO EXPRESS
7 = 4-digit ADEMCO CONTACT ID® REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
0 = Standard/backup reporting only (all to primary)
Primary Phone No.
2nd Phone No.
1 = Alarms, Restore, Cancel
2 = All except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel
4 = All except Open/Close, Test All
5 = All
0 = no delay UL: must be "0"
1 = 15 seconds
2 = 30 seconds
3 = 45 seconds
0 = Radionics (0-9, B-F)
1 = SESCOA (0-9 only reporting)
Select "0" for all other formats.
Select delay from 0 to 225 secs, in 15-sec increments.
0 = no delay (both signals sent), 1 = 15 secs,
2 = 30 secs, etc.
UL: Grade AA must be "0;" Grade A must be "15" max
0 = Primary Dialer first; 1 = Long Range Radio first.
For UL Commercial Burglary installations that use a
DACT and LRR, this field must be "0".
Others
All
All
SIA Installations: delay
must be minimum of
30 seconds