Avoid aiming directly at a fluorescent light. Keep at Ieaat
20ft (6.1 m) away from them if possible. They present
variable reflections to the microwave aeneor.
* Microwave
transmission
penetrate
most
building
material (except metal, which reflacts transmission).
Moving objects outside of the protected
area may,
therefore, be detected unless the microwave sensitivity
control is kept at as low a sening as possible, to mini-
mize penetration,
Make
sure
the
detection
area
does
not
have
obstructions (cutiains, screens, large pieces of furniture,
plants, etc.) which may block the PIR portion of the
coverage pattern.
Impotiant Avoid running alarm wiring close to heavy duty
electrical power cables,
INSTALLATION
Mounting
1. Remove front cover by twisting a screwdriver blade in
the groove between cover and base at the location
shown in Diagram 2 and then bffing the cover off,
2. Mount wall plata to a firm vertical surface (flat on wall
or in corner). Position the plate ao that field wiring is
centered in the hole at the top of the plate [wall wiring
hole no larger
than 5/16
(8mm)
diameter].
See
Diagram 3,
3. Feed wiring through the wiring hole in the bracket, and
via the wiring trough at the rear of the base through the
wiring hole in the base. Do not connect to terminal
block yet.
4. Attach unit to wall plata by engaging all four hooks on
the plate into slots on the rear of the base and by
sliding the unit downward, See Diagram 3.
Note: The unit is locked to the wall plate by a plastic
spting tab in the plate that engages an opening in
the housing base (sea Diagram 3). The unit can
only be removed from the plata by removing the
cover, depressing the tab (via a hole in the base)
with a small blade screwdriver, and then stiding the
unit upward (see Diagram 4),
Use of the wall plate provided is recommended.
If you
choose
nOt to
use the wall plate, knockout holes for direct
wall or corner mounting are provided in the unit's base (to
gain access to them, the circuit board must be carefully
removed from the base by bending back the circuit board
holding tab at the Iowar edge of the board). Do not use the
unit$ "wall plate keyholes" for direct mounting; use the
mounting holes above the ,Ckeyholes"(or to the left and
right of the 'keyholes" for corner mount).
I
1
1I
mIST
scRNDRY=R BMDEINGROOvE.
21
Ll~ COVEROFF,
u
<y
D~ECTOR
LOCKING
TAa
no
~
@
[~
MOUNTING HOLES
WALL (3)
CORNER (4)
Diagram 3
WALL PLATE
Wiring Ccmnactions
(see Diagram
4)
Bring all wires through the unifs wiring ent~
near the
terminal block and make connections
as indicated
in
Diagram 4 and in the table below.
TERM
FUNCTION
1
+12 Vlnput
Supply.
Powar muat be provided
from a 12VDC
filtered
source
with 25mA
capability
and at least 4 hours of standby
batfe w caoacitv.
2
(-) Input Supply (ground).
3&4
Relay Contacts.
N.C.(open on alarm),
Connect to closed protective circuit,
5
Alarm LED Remote Disable.
Apply+12Vto.
_
disable-alarm
indication (Same assening
DIP
switch #3 UP).
6
Trouble Output. Upon aupewision failure, this
open collector
output will go low (requires
1000-ohm pull-up resistor). Useahielded
wire
for UL installations.
Locally, both LEDs will flash to annunciate
trouble. The detector continues to operate as
PIR only.
Adjustments
and Selections
MICROWAVE SENSITIVIW
CONTROL:
Turn the Potentiometer clockwise to increase sensitivity.
DIP SWITCH S~lNGS:
#1: UP for Walk Teat selection (relay will remain open
while Test is eelected),
#2: UP for setting Pulse Count to 3.
#3
UR foralarm LED
daable
(disables
alarm indication
only).
#4
UNUSED
TESTING
Irrrpomant Wait at Iaast two minutes after applying power
before attempting to walk-test unit.
Conduct the walk testing of the detector with the protected
area
cleared
of
all
people,
[n
come
business
establishments, it may be more convenient to do ttis afler
the business ia closed, The protective system's control
should be disarmed
during the procedure
to prevant
-
repoting unwanted alarms.